Mounting Of Video Control Device; Technical Data Of Video Control Device - Gira 1288 00 Operating Instructions Manual

System manual, video control device
Table of Contents

Advertisement

Mounting of video control device

Technical data of video control device

18
Attention
Installation and mounting of electrical devices may only be
carried out by a qualified electrician.
For installation protected from dripping and sprayed water,
mount the control device to a top-hat rail in the distribution.
The mains and bus connection is made via screw terminals.
The mains connection must be made via an all-pole mains
switch with at least a 3 mm contact opening.
The function earth line must be connected via a distributor
block.
The ventilation slits of the control device must not be blocked.
Primary rated voltage:
Secondary rated voltage:SELV 26 V DC ± 2 V
Secondary rated current: 700 mA continuous load
Protection type:
Screw terminals:
Door opener output:
Door opener time:
Power-on time
of door opener:
Operating temperature: - 5 °C to + 45 °C
Dimensions:
AC 230 V, 50 Hz
Overload deactivation
from approx. 900 mA
1.15 A peak load (max. 5 seconds)
IP 20
0.6 mm
to 2.5 mm
12 V AC, 1.1 A (switched for the
set door opener time)
adjustable, 1 to 10 seconds
25% (max. 10 seconds ON,
then 30 seconds OFF)
8 modules, series inst. housing
2

Hide quick links: