Displaying Operating Information - Riello RiCloud User Manual

Hide thumbs Also See for RiCloud:
Table of Contents

Advertisement

3.11
Displaying operating
information
This function (available with OTBus
connection between the WiFi Box
and the boiler or the RF receiver and
the boiler or RiCLOUD and the boiler,
if provided for by the OTBus protocol)
allows you to display the boiler probe
values and some boiler operating
statuses.
From the HOME screen, press the SET/
PROGRAM button to open the user
menu.
Press the FORWARD
to select the field InFO.
Parameter
tSEt
EXAMPLE:
The heating delivery setpoint calculated by RiCLOUD is 30°C, the minimum
boiler heating setpoint parameter is 40°C, the real heating delivery setpoint
delivered by the boiler is 40°C.
tFLO
or BACK
button
Heating delivery setpoint calculated by
RiCLOUD (shown only if RiCLOUD has received
a heating request). The value calculated by
RiCLOUD may differ from the real heating
delivery setpoint delivered by the boiler, if the
minimum boiler heating setpoint parameter
is higher than this value.
Temperature read by the boiler heating
delivery
connection between the WiFi Box and the
boiler or the RF receiver and the boiler or
RiCLOUD and the boiler, if provided for by the
OTBus protocol).
Press the SET/PROGRAM button to
display this field.
Press the UP
or DOWN
select the desired parameter and wait
until it is displayed.
Description
probe
(available
76
button to
with
OTBus

Advertisement

Table of Contents
loading

Table of Contents