3.5
Setting the operating
mode
From the HOME screen, press ESC/
MODE repeatedly
to select one of the following modes:
3.5.1
OFF mode
In OFF mode, RiCLOUD guarantees
the minimum room temperature set
at parameter 01 from the PL technical
menu only.
NOTE
Only if the boiler is in the correct
operating condition (i.e. powered
and not blocked).
In case of an OTBus connection
between the WiFi Box and the boiler
(including other types of connection
via OTBus), the boiler remains OFF if
all RiCLOUD thermostats in the system
are OFF . When the boiler is OFF it does
not provide any heating or domestic
hot water.
3.5.2
SUMMER/DHW mode
RiCLOUD in SUMMER/DOMESTIC HOT
WATER mode. In this mode, the boiler
provides domestic hot water where
requested (instant boiler).
If the parameter 24 CLOC is set to ON;
RiCLOUD follows the time periods set
in the user-programming menu for
DHW, pre-heating the water in the
storage tank (only for boilers with
integrated tank).
The minimum room temperature set
at parameter 01 from the PL technical
menu is, however, guaranteed.
In case of an OTBus connection
between the WiFi Box and the boiler
(including other types of connection
via OTBus), the boiler remains in
SUMMER mode if at least one of the
thermostats is in summer mode and
the others are OFF .
67