4.1

P01-PLU Data

1. From the program mode main menu screen, press the down arrow once to scroll to P01 PLU.
2. Press
to display P01-00 PLU.
Enter
3. Enter the PLU number.
4. Press
. 13001-0000 ENT OR CLR displays.
PLU
5. Press
to confirm. P01-01 < SALE1 > displays.
Enter
6. Press
. INP 0001-0000 00 displays
Edit
7. Enter/edit text. See
8. Press
. P01-01 < SALE1 > displays.
Enter
9. Press
to enter the lower level menus.
Enter
Parameter
Display
P01-01
P01-01-01 SALES
Sale1
P01-01-02 MD MODE
P01-01-03 OPEN PRICE
P01-01-04 PRICE
P01-01-10 TARE
P01-01-12 P TARE
P01-01-13 FORCED TARE
P01-01-14 LO WGT
P01-01-15 UP WGT
P01-03
P01-03-01 NUT.
MSG.
P01-03-02 — P01-03-04
MSG1-3
P01-03-07 COOK
P01-04
P01-04-01— P01-04-03
IMAGE
IMAGE 1-3
P01-04-05 S H IMG
P01-04-06 S H IMG PRN
Section 5.2 on page
28.
Enter the mode number. Press
To delete the PLU press
Enter the mode number. Press
Enter the mode number. Press
operator to change the price.
Enter the unit or fixed price. Press
Enter tare weight. Press
Enter the tare percentage. Press
Example: Enter 60 for a 6.0% tare.
Enter the mode number. Press
is required to print a label.
Enter the lower weight limit. Press
Enter the upper weight limit. Press
Enter the desired Nutrition Facts number. Press
Enter the desired Extra Message number. Press
Enter the desired Cook Time number. Press
Set the image to print on the label. The label format must be configured to
support variable images. Press
Leave at 0. The SH image is specified in the label format.
Enter the mode number. Press
image in the Safe Handling Image Print display.
Table 4-1. P01 PLU Data
Description
Enter
to select a desired sales mode.
Zero
at this step.
Enter
to select a desired markdown mode. 0: NORMAL
Enter
to select whether or not to allow the
Enter
.
Enter
.
Enter
. Format is X.X%
Enter
to select whether or not a tare weight
Enter
.
Enter
.
Enter
Enter
to select.
Enter
to select whether or not to print the
© Rice Lake Weighing Systems ● All Rights Reserved
Program Mode
0: WEIGHT
1: FIX PRI
2: WGT F/PRI
1: SPECIAL
2: -$
3: -%
4: SPEC. U/P
5. U/P -$
6: U/P -%
0: YES
1: NO
--
--
--
1: YES
2: NO
--
--
Enter
--
to select.
Enter
--
to select.
--
to select.
--
0
1: NO PRINT
2: PRINT
Choices
17