C5 Mode ⋅⋅⋅⋅ Program No. display
3.3.6
1. C5 Mode setup
Press the ten-key 5 and confirm it by pressing the
TARE key.
2. Ending program No. display
Press the UNDER key.
3.3.7 C6 Mode ⋅⋅⋅⋅ E2ROM initialization (Registration ⋅ set data/all)
1. C6 Mode setup
Press the ten-key 6 and confirm it by pressing the TARE
key.
2. Registering and initializing set data
Press the ZERO key twice.
3. Complete Initialization (registration ⋅ setup ⋅ scale data)
For execution, press the memory switch on the main
board.
Then, buzzer sounds.
Reference
Reference
• For the memory switch location, refer to span adjustment
at page 27.
Data after initialization
4. Country number:
5. Weighing capacity No.: 20 (150kg)
6. Weight span data:
4. Ending initialization
Press the UNDER key.
The program starts at Test Mode when the initialization
flag is set. The flag is reset when span adjustment is
performed, and the normal mode then becomes
available.
Operation
Operation
10 (Japan)
Approximate value
28/54
Display
Display
Input data
RAM clear
EEPROM clear
Note
Be sure to perform span adjustment
using a weight.
IWQ Series Service Manual
o k