[15]

Priority Alarm and Restoral Reporting Codes

These reporting codes are used by the communicator to transmit the following list of alarm and restoral conditions.
Use instructions in Section [07] as a guide for programming.
Refer to the Terminal Connections section of this manual for information on the Auxiliary Input Zone operation; Section
[31] contains options for the Auxiliary Input Zone.
The Cross Zoning Code will be transmitted when two different alarms occur during the same armed or disarmed period.
The Cross Zoning Code will only be transmitted once during each armed or disarmed period. NOTE: The Cross Zoning
Code will not be affected by the Transmission Delay. If another alarm occurs during a Transmission Delay, the delay
will be terminated and all events will be transmitted immediately.
Reporting Codes are programmed for the following events:
• Auxiliary Input Zone Alarm / Closing
• [P] Key Alarm
• [F] Key Alarm
• [A] Key Alarm
[16]

Maintenance Alarm Reporting Codes

Program eight 2-digit reporting codes for the following events:
• Low Battery Alarm: transmitted when the battery voltage drops below 11.3 volts. This reporting code will also be
transmitted to report a battery fuse failure. The battery is tested under load every 10 seconds or 4 minutes,
depending on the option selected in Section [26].
• Mains (AC) Failure Alarm: transmitted to report an AC power failure after the delay time programmed in Section [19].
The delay time prevents transmissions during temporary power failures.
• Bell Fuse Trouble Alarm: transmitted when the bell circuit is open or if the bell fuse has failed.
• Fire Trouble Alarm: transmitted if the fire zone goes open (end-of-line resistor is disconnected).
• AUX Supply Trouble Alarm: transmitted when the auxiliary power supply fuse fails.
• Downloading Lead-in
• Downloading Lead-out: Refer to the Downloading section of this manual for information on the Downloading Lead-
in and Lead-out codes.
• Keypad Tamper Trouble: Keypad Tamper Troubles apply to systems using the DSC LED625T or LCD600T keypads.
These keypads feature tamper switches which are activated when the keypad is removed from its backplate.
Keypad Tamper Trouble is enabled in Section [26]; refer to "Displaying Trouble Conditions: [ ]+[2]" in the Keypad
Functions section of this manual for information on how keypad tamper troubles are indicated and reported.
Refer to [ ][2] Trouble Command for additional information on trouble codes and transmissions.
[17]

Maintenance Restoral Reporting Codes

Program eight 2-digit restoral codes for the event described in Section [16]. The Telephone Line Monitoring Restoral,
Test Transmission and Lockout Reporting Codes are also programming in this section.
The Telephone Line Monitoring Restoral Code is transmitted after the telephone line has been restored for at least 20
seconds. Refer to TLM Options in Section [21], Zone Light 1 and 2.
The Test Transmission Code can be sent immediately by entering [ ][6][Master Code][8]; refer to System Test in the
User Function Command section of this manual. If Section [22] Zone Light 3 is OFF, the test transmission will be sent
at the day interval programmed in Section [19] and at the time programmed in Section [32]. If Hourly Test Transmission
is enabled (Section [22] Zone Light 3 ON), test transmissions will be sent every hour on the hour. If Test Transmission
Every 15 minutes is selected (Section [22] Zone Light 4 ON), a test transmission will be received every 15 minutes.
NOTE: This test transmission is only sent when the system is armed.
"Test Transmission Every 15 Minutes" takes precedence over "Hourly Test Transmission" if both are enabled.
The Keypad Lockout Code is transmitted when the maximum number of attempts to enter an Access Code is
reached. Refer to Section [39] Keypad Lockout Options for more information on the Keypad Lockout Function.
• Auxiliary Input Restore / Opening
• [P] Key Restoral
• [F] Key Restoral
• [A] Key Restoral
• Cross Zoning Code