DSC PC2585 Installation Manual page 46

Software version 1.1r dls-1 v6.2kr and up
Table of Contents

Advertisement

1.1R
PC2585 Version
[21]
Second System Option Code
Default
OFF
Zone Light 1
OFF
Zone Light 2
OFF
Zone Light 3
OFF
Zone Light 4
ON
Zone Light 5
OFF
Zone Light 6
OFF
Zone Light 7
OFF
Zone Light 8
[22]
Third System Option Code
Default
OFF
Zone Light 1
OFF
Zone Light 2
OFF
Zone Light 3
OFF
Zone Light 4
ON
Zone Light 5
ON
Zone Light 6
ON
Zone Light 7
OFF
Zone Light 8
[23]
Fourth System Option Code
Default
OFF
Zone Light 1
OFF
Zone Light 2
ON
Zone Light 3
ON
Zone Light 4
OFF
Zone Light 5
OFF
Zone Light 6
OFF
Zone Light 7
OFF
Zone Light 8
[24]
Fifth System Option Code
Default
OFF
Zone Light 1
OFF
Zone Light 2
OFF
Zone Light 3
OFF
Zone Light 4
OFF
Zone Light 5
OFF
Zone Light 6
ON
Zone Light 7
OFF
Zone Light 8
42
Page 24
Zone Light ON
TLM disabled
TLM trouble sounds bell when armed
Alarms restore on bell time-out
Swinger Shutdown resets at 12:00 am
Bell shutdown enabled
Bell output always pulsed
Bell output inverted
User DLS window enabled
Page 24
Zone Light ON
PO3: FTC output
PO4: TLM and Alarm output
Hourly Test Transmission
Test Transmission every 15 minutes
Bell silent for FTC
Downloading Annunciation enabled
ID Tone/Panel Answer Ack. enabled
2100Hz ID/Panel Answer Ack. Tone
Page 25
Zone Light ON
Send Identified Partial Closings
Auto-Arm sends Partial Closing Code
Access Code needed to cancel Auto-Arm
Access Code needed to bypass zones
Master Code not user-programmable
One-Time Use Code enabled
Quick-Exit enabled
SW AUX resets for 5s on Arming
Page 25
Zone Light ON
Normally Closed zone loops
Single End-of-Line Resistor Zones
Zones bypassed for 120s on power-up
Force Arm with AUX zones
Home Away Zones have Entry/Exit Delays
Bell sounds for [P] Key alarms
Keypad sounds for [P] Key alarms
[F] Key disabled
Zone Light OFF
TLM enabled
TLM silent
Alarms restoral follows zone restoral
Swinger Shutdown resets on arming
Bell shutdown disabled
Bell output follows zone type
Bell output normal
User DLS window disabled
Zone Light OFF
PO3: Strobe output
PO4: System Status output
Test Transmission as per times in [19] & [32]
Normal Test Transmission
Bell sounds for FTC
Downloading Annunciation disabled
ID Tone/Panel Answer Ack. disabled
1300Hz ID/Panel Answer Ack. Tone
Zone Light OFF
Partial Closings not identified
Auto-Arm does not send Partial Closing Code
Any keypress cancels Auto-Arm
Access Code not required to bypass zones
Master Code user-programmable
One-Time Use Code disabled
Quick-Exit disabled
SW AUX does not reset on Arming
Zone Light OFF
Double End-of-Line Resistor zone loops
Zones use setting in Section [24] Light 1
Zones active on power-up
No Force Arm with AUX zones
No Delays for Home Away Zones
Bell Silent for [P] Key alarms
Keypad silent for [P] Key alarms
[F] Key enabled

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents