4.2.1

Auto-start

Auto-start Settings
Auto-start _
seconds after
DC applied
Buzzer on
NOTE
For new parameters to take effect, you must click on
follow procedure instructions. Please refer to the relevant section for details.
PB-2500J-PCIe/ CSM
If the "Auto-start" box is checked, the system will start __
seconds after the 3-pin pluggable terminal block is plugged
into the system (DC applied).
If the "Auto-start" box is not checked, once you have plugged
in the 3-pin pluggable terminal block, you will need to press the
power button to turn the system on.
If the "Buzzer on" box is checked, a buzzer sound will sound
as soon as the supercapacitors start to discharge (supplying
power to the system).
If the "Buzzer on" box is not checked, no buzzer sound will be
made when the supercapacitors start to discharge.