Yeastar Technology S300 Installation Manual

Yeastar Technology S300 Installation Manual

Voip pbx
Hide thumbs Also See for S300:

Advertisement

Yeastar S300 VoIP PBX
Installation Guide
Sales Tel: +5411.4951.3104 #1
E-mail: ventas@rcmphones.com
Support Tel: +5411.4951.3104 #2
E-mail:soporte@rcmphones.com
Web: http://www.rcmphones.com
Version: 1.2
Date: 2016.09.02

Advertisement

Table of Contents
loading

Summary of Contents for Yeastar Technology S300

  • Page 1 Yeastar S300 VoIP PBX Installation Guide Sales Tel: +5411.4951.3104 #1 E-mail: ventas@rcmphones.com Support Tel: +5411.4951.3104 #2 E-mail:soporte@rcmphones.com Web: http://www.rcmphones.com Version: 1.2 Date: 2016.09.02...
  • Page 2: Table Of Contents

    Yeastar S300 Installation Guide Content Welcome……………………………………………………………………………………………………….3 Before You Start……………………………………………………………………………………………...4 Package Contents…………………………………………………………………………………………..4 Expansion Board……………………………………………………………………………………………4 Yeastar S300 Overview…………………………………………………………………………………….5 LED Indicators and Ports…………………………………………………………………………………..6 Installation…………………………………………………………………………………………………….8 Safety Disclaimers and Installation Warnings……………………………………………………………8 Telephony Module Installation……………………………………………………………………………..8 DSP Module Installation…………………………………………………………………………………..11 Hard Disk Installation……………………………………………………………………………………..12 Desktop Installation……………………………………………………………………………………….13 Rack Installation…………………………………………………………………………………………..13 Ground Connection……………………………………………………………………………………….14 Connecting the Equipment……………………………………………………………………………….15...
  • Page 3: Welcome

    24 analog ports, up to 24 BRI ports, up to 3 E1/T1/PRI ports, and up to 6 GSM channels. This guide describes how to install the S300 and how to log in the web GUI to configure the system. Once you complete the installation, refer to the Yeastar S-Series Administrator Guide for instructions on how to perform configurations on the system.
  • Page 4: Before You Start

    Yeastar S300 Installation Guide Before You Start Before you begin to install the S300 IP Phone System, please check the package contents to verify that you have received the items below. If there is any problem, please contact your provider.
  • Page 5: Yeastar S300 Overview

    Yeastar S300 Installation Guide Expansion Board – EX30 EX30 board supports 1 E1/T1 port. D30 Module D30 is a DSP module, used to expand the capacity of PBX. With per D30 module added, the extensions increase 100 and concurrent calls increase 30 in additional.
  • Page 6: Led Indicators And Ports

    Yeastar S300 Installation Guide Back Panel Antenna Sockets SD Slot Console Power Switch Power Power Inlet System Protective Earth Reset USB Slot LED Indicators and Ports LED Indicators Indication Status Description The power is switched on POWER Power status The power is switched off...
  • Page 7 Connect a USB drive or mobile hard disk drive. SD Slot Insert a SD card. Yeastar S300 provides two 10/100/1000 Mbps adaptive RJ45 Ethernet ports. There are 3 Ethernet modes for the system. The default mode is “Single”.  Single: LAN port interface will be used for uplink connection. WAN port is Ethernet Port disabled.
  • Page 8: Installation

    Before cleaning the device, cut off the power supply.  Environment Install the Yeastar S300 IP PBX in a location that is clean, free from vibration, electric shock, and temperature/humidity extremes. The operating temperature should be kept below 104° F (40° C). Telephony Module Installation STEP 1 Loosen the screws on the enclosure and then remove the upper cover.
  • Page 9 Yeastar S300 Installation Guide STEP 2 Push out the empty board from the inside of the device. STEP 3 Push in the Expansion Board (EX08 or EX30). STEP 4 Lock the screws to fix the Expansion Board. 9/16...
  • Page 10 Yeastar S300 Installation Guide STEP 5 Insert the Telephony Modules on the EX08 Board. Skip this step for EX30 Board. STEP 6 Insert a SIM card on the GSM/3G module following the instructions. Skip this step if no GSM/3G module installed.
  • Page 11: Dsp Module Installation

    Yeastar S300 Installation Guide STEP 8 Rotate the antenna into the Antenna Socket. Skip this step if no GSM/3G module installed. DSP Module Installation STEP 1 Open the device upper cover and insert the DSP module (D30) into the D-Slot from a tilt angle and then press it down.
  • Page 12: Hard Disk Installation

    Yeastar S300 Installation Guide Hard Disk Installation STEP 1 Lock the hard disk on the bracket and push the hard disk into the bracket. STEP 2 Lock the screw to fix the hard disk. 12/16...
  • Page 13: Desktop Installation

    Yeastar S300 Installation Guide Desktop Installation WARNING  Please set 5~10cm gaps around the device for air circulation.  Please avoid any heavy thing placed on the device. STEP 1 Place the IP PBX on a steady platform. STEP 2 Remove the adhesive backing paper from the rubber feet.
  • Page 14: Ground Connection

    Yeastar S300 Installation Guide STEP 2 Place the PBX in the 19-inch rack and fix both brackets to the rack with the rack’s proprietary mounting equipment. Ground Connection WARNING  Proper grounding (connection to ground) is very important to reduce the risk to the user of electrocution or protect the PBX from the bad effects of external noise in the case of a lightning strike.
  • Page 15: Connecting The Equipment

    LAN switch/router. STEP 2 Plug the provided power cord into the power jack on S300 and the other end to a standard electrical wall socket. Wait for the system to boot up till the SYSTEM LED starts to blink.
  • Page 16: Getting Started With The Configuration

    Yeastar S300 Installation Guide Getting Started with the Configuration Yeastar S300 IP Phone System provides web-based configuration interface for administrator. The administrator can manage the device by logging in the Web interface.  Access path: https://192.168.5.150:8088  User Name: admin ...