6 Related Parameters
No.
Name
(Addr. Hex)
F1-21
PG 1 Option
(3BC)
Function
<3>
F1-30
Motor 2 PG
(3AA)
Connector
<6>
F1-31
PG 2 Pulse
(3B0)
Setting
<2> <7>
F1-32
(3B1)
PG 2 Rotation
<7>
F1-33
PG 2 Gear
(3B2)
Teeth 1
<5> <7>
F1-34
PG 2 Gear
(3B3)
Teeth 2
<5> <7>
F1-35
PG 2 Division
(3BE)
Ratio for Pulse
Monitor
<7>
F1-36
PG 2 Hardware
(3B5)
Disconnect
<7>
F1-37
PG 2 Option
(3BD)
Function
<7>
<1> Veries by drive models.
<2> The number of output pulses for the PG can be calculated as follows:
Motor speed at maximum frequency output (min
f
(Hz)
PG
<3> The parameter is available only for the drive connector CN5-C.
<4> Value changes according to the control mode selection in A1-02.
<5> Enabled only when using the V/f with PG control mode.
<6> Depending on the drive series, a second PG (PG 2) may not be possible. Refer to the Yaskawa AC Drive Technical
Manual for the drive in your application
<7> The parameter is available only for the drive connector CN5-B.
24
Description
0: A pulse detection
1: AB pulse detection
Selects the connector for the PG option connected to
motor 2.
0: CN5-C
1: CN5-B
Sets the pulses to be read from the pulse generator.
0: Forward = A pulse leads
1: Forward = B pulse leads
Number of gear teeth between the PG and motor.
Pulses × 60
×
F1-31
A gear ratio of 1 will be used if any of these
parameters is set to 0.
Sets the division ratio for the pulses output from the
PG encoder. Set as a three-digit number where x is
the first digit, y is the second digit, and z is the third
digit:
(1 + x)
Ratio =
yz
When only the A pulse is read, this ratio is disabled
and pulses are set as 1/32 to 1.
0: Disabled. No fault if the connection is lost.
1: Enabled. Fault if connection is lost.
0: A pulse detection
1: AB pulse detection
60
YASKAWA ELECTRIC TOBP C730600 37B 1000-Series Option PG-X3 Installation Manual
F1-33 (load side)
F1-34 (motor side)
-1
)
× PG rating (p/rev)
Control
Values
Method
Default: 0
V/f w/ PG
Range: 0, 1
V/f w/ PG
Default: 1
CLV
Range: 0, 1
Default: 1024
V/f w/ PG
Min: 0
CLV
Max: 60000
V/f w/ PG
Default: 0
CLV
Range: 0, 1
Default: 0
V/f w/ PG
Min: 0
Max: 1000
Default: 1
V/f w/ PG
Min: 1
CLV
Max: 132
V/f w/ PG
Default: 1
CLV
Range: 0, 1
Default: 0
V/f w/ PG
Range: 0, 1