Download Print this page

YASKAWA PG-X3 Installation Manual page 22

Ac drive 1000-series option
Hide thumbs Also See for PG-X3:

Advertisement

No.
Name
(Addr. Hex)
F1-05
(384)
PG 1 Rotation
<3>
F1-06
PG 1 Ratio for
(385)
PG Pulse
Monitor
<3>
F1-08
PG Overspeed
(387)
Level
F1-09
Overspeed Det.
(388)
Time
Excessive
F1-10
Speed
(389)
Deviation Det.
Level
Excessive
F1-11
Speed
(38A)
Deviation Det.
Time
F1-12
PG 1 Gear
(38B)
Teeth 1
<3> <5>
F1-13
PG 1 Gear
(38C)
Teeth 2
<3> <5>
F1-14
PG Disconnect
(38D)
Det. Time
F1-18
Reverse
(3AD)
Rotation Det.
for PG 1
<3>
F1-19
Reverse
(3AE)
Rotation Det.
for PG 1
<3>
F1-20
PG 1 Hardware
(3B4)
Disconnect
<3>
YASKAWA ELECTRIC TOBP C730600 37B 1000-Series Option PG-X3 Installation Manual
Description
0: Forward = A pulse leads
1: Forward = B pulse leads
Sets the division ratio for pulses output from the PG
encoder. Set as a three-digit number: x is the first
digit, y is the second digit, and z is the third digit:
X3
(1 + x)
Ratio =
yz
When only the A pulse is read, this ratio is disabled
and pulses are set as 1/32 to 1.
Sets the level for detecting overspeed as a percentage
of the maximum output frequency.
Sets the time required for the motor to exceed the the
level set in F1-08 to trigger a fault.
Sets the degree of speed deviation to trigger a dEv
fault. Set as a percentage of the maximum output
frequency.
Sets the time required a speed deviation situation to
trigger a fault.
Number of gear teeth between the PG and motor.
Pulses × 60
F1-13 (load side)
×
F1-01
F1-12 (motor side)
A gear ratio of 1 will be used if any of these
parameters is set to 0.
Sets the time in seconds for PG disconnect to be
detected.
0: Disabled
n: Number of times a dv3 situation must be detected
to trigger a fault.
0: Disabled
n: Number of times a dv4 situation must be detected
to trigger a fault.
0: Disabled. No fault if the connection is lost.
1: Enabled. Fault if connection is lost.
6 Related Parameters
Control
Method
V/f w/ PG
Default:
CLV
Range: 0, 1
CLV/PM
V/f w/ PG
Default: 1
CLV
Min: 1
CLV/PM
Max: 132
V/f w/ PG
Default: 115
CLV
Min: 0
CLV/PM
Max: 120
AOLV/PM
V/f w/ PG
Default:
CLV
Min: 0.0
CLV/PM
Max: 2.0
AOLV/PM
V/f w/ PG
Default: 10
CLV
Min: 0
CLV/PM
Max: 50
AOLV/PM
V/f w/ PG
Default: 0.5
CLV
Min: 0.0
CLV/PM
Max: 10.0
AOLV/PM
Default: 0
V/f w/ PG
Min: 0
Max: 1000
V/f w/ PG
Default: 2.0
CLV
Min: 0.0
CLV/PM
Max: 10.0
Default: 10
CLV/PM
Min: 0
Max: 10
Default: 128
CLV/PM
Min: 0
Max: 5000
V/f w/ PG
Default: 1
CLV
Range: 0, 1
CLV/PM
Values
<1>
<4>
23

Hide quick links:

Advertisement

loading