High Salt: Led On - Hayward AquaRite series Troubleshooting Manual

Salt system
Hide thumbs Also See for AquaRite series:
Table of Contents

Advertisement

The High Salt LED will appear ON solid when the maximum allowable cell amperage
has been reached. The AquaRite control center will shutdown all chlorine production
Test the Salt Level
Step 2A
Desired Salt
Concentration:
3200PPM
Test salt concentration of the water using an
independent test, with a calibrated salt meter. IF salt is
above 3400, go directly to 2G. IF the salt level is correct,
proceed to step 2B.
NOTE: High water temperatures (typically found in smaller bodies of water, such as spas) can cause
the High Salt LED to trigger when the salt concentration favors the high end of the range. If the
water temperature is high, then consider diluting the salt level down between 2700-3200ppm.
19

2. High Salt: LED ON

until the problem is solved and the LED light clears.
Correct Cell Programmed?
Step 2B
Verify the cell model programmed into the control
center, matches the model listed on the cell. IF it does
not match, change programmed cell
correct, go to step 2C.
(refer to pg.
9). IF