To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely. PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Hayward Pool Products (Australia) Pty Ltd. Melbourne-Sydney-Brisbane-Perth Email: sales@hayward-pool.com.au | Website: www.hayward-pool.com.au PO Box 4384 | Dandenong South VIC 3164...
WARNING – Use only genuine Hayward replacement parts. WARNING – If the power supply cord is damaged the device must not be used. The power supply cord must be replaced by the manufacturer or similarly qualified persons to avoid any danger.
NOTE: The use of dry acid (sodium bisulfate) to adjust pool pH is discouraged especially in arid regions where pool water is subject to excessive evaporation and is not commonly diluted with fresh water. Dry acid can cause a buildup of by-products that can damage your chlorinator cell. COMPONENTS Master Unit Slave Unit ® USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 3...
They can have separate filtration systems or share a common filter with a singular filtration pump. Each unit must have its own Flow Switch installed as per the diagrams on pages 5 and 7. ® USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 4...
Page 5
IMPORTANT: There must be at least 30 cm of straight pipe run before (upstream) the Flow Switch. If mounted before the Flow Switch, the T-Cell can count as the 30 cm of straight pipe. ® USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 5...
Pull Unscrew Dead Front Panel: Remove the six (6) screws fastening the panel to the unit. Once all loose, lift the panel off the unit to access the PCB. Unscrew Unscrew ® USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 6...
The above diagram is a schematic only, and the flow switch wire is not to be pulled apart into to seperate single insulated conductors further than what is required to make the joins/connections inside the Slave unit housing. ® USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 7...
The AquaRite+ AU is to be connected to a GPO with a permanent power supply only. CAUTION - This circuit must be protected by a residual current device (RCD) with a fixed residual ________ operating current not exceeding 30 mA. ® USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 8...
If the Master unit does not want the Slave unit to produce chlorine, the slave unit will display “FLOW” alert on the display until it is called into action at which point it will display Pol 1 or Pol 2. ® USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 9...
Page 10
When the heater will be running there will be a differential reading between the two units due to the different points of measurement in the plumbing. ® USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 10...
Page 11
In this situation the Slave unit would still be called to come on if the ORP/Redox level fell below 2% of the set point but would only be for a very short period of time. ® USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 11...
Page 12
Hayward Pool Products (Australia) Pty Ltd. Melbourne-Sydney-Brisbane-Perth Email: sales@hayward-pool.com.au | Website: www.hayward-pool.com.au PO Box 4384 | Dandenong South VIC 3164 ABN 66 083 413 414 Sales Contact Ph: 1300POOLS1 Fax: 1300POOLS2 Hayward and AquaRite are registered trademarks of Hayward Industries, Inc.