How To: Clean the TurboCell (Cont.)
The Inspect Cell LED, when flashing alone, indicates that the system is recommending
the TurboCell should be inspected and cleaned (if necessary). The LED will flash alone
every 500 operational hours as a reminder to inspect and/or clean the TurboCell.
Thoroughly Rinse Cell & Return
Step 5
After the solution has been safely removed, thoroughly
rinse the TurboCell before returning it to its place in the
plumbing. Once returned turn the pump back ON and
proceed to the step 6.
NOTE: If the cell was reading a low salt level prior to cleaning, the average salt may need to be
reset. To reset the average salt level, follow the steps outlined on pg.10 or wait 24 hours for the
14
system to acclimate to the recent changes.
Reset: Inspect Cell (if applicable)
Step 6
IF the "Inspect Cell" LED was flashing alone, press and
hold the diagnostics button for 5 seconds OR until the
Inspect Cell LED goes out. This will reset the inspect
cell timer for another 500 operational hours.