Panasonic VF0 Series Instruction Manual page 83

Compact inverter 400v class
Hide thumbs Also See for VF0 Series:
Table of Contents

Advertisement

Inspection
Operation
checks
All parts
Capacitor
Cooling
fan
Display
unit
Meter
General
Downloaded from
www.Manualslib.com
Check item
item
(1) Check output line
voltage balance
between phases
during inverter
operation without
application.
(2) Check the
protection and
display circuits
with the
sequence
protection
operation test.
(1) Any strange
smells or
discoloration?
(2) Is there heavy
rusting?
Any trace of liquid
leaks or
deformation?
(1) Is there any
abnormal
vibration or
abnormal noise?
(2) Are any of the
connections
loose?
Are any LEDs not
working?
Are all readings
correct?
(1) Is there any
abnormal
vibration or
abnormal noise?
(2) Strange smells?
manuals search engine
Check
Check method
frequency
(1) Measure voltage
between output
terminals.
(2) Simulate a
short-circuit
between the
inverter warning
outputs.
(1), (2)
Visual inspection
and smell
Visual inspection
(1) Audible check
(2) Tighten
fastenings
Visual inspection
Check indicated
value
(1), (2)
Visual, audible and
smell test
Test criteria
Instrument
(1) Line output
balance is 4V
max.
Rectifier type
voltmeter
(2) The sequence
protection circuit
must function
correctly.
(1), (2) Normal
Normal
(1), (2) Normal
Normal
Must be within
Voltmeter
standard value and
Ammeter
control value.
(1), (2) Normal
82

Advertisement

Table of Contents
loading