PRESET FREQUENCIES 2 to 8 (Parameter P32 to P38)
Used to program the speeds 2 to 8, frequencies for multi-step speed operation.
[Parameter P32 : Speed 2 frequency setting]
[Parameter P33 : Speed 3 frequency setting]
[Parameter P34 : Speed 4 frequency setting]
[Parameter P35 : Speed 5 frequency setting]
[Parameter P36 : Speed 6 frequency setting]
[Parameter P37 : Speed 7 frequency setting]
[Parameter P38 : Speed 8 frequency setting]
Data setting range
Setting unit
Note)
2nd ACCELERATION TIME and 2nd DECELERATION TIME
Used to set the 2nd acceleration/deceleration time selected with the 2nd characteristics
selection switch.
[Parameter P39 : 2nd acceleration time setting]
[Parameter P40 : 2nd deceleration time setting]
Data setting range
Setting unit
Downloaded from
www.Manualslib.com
(Hz) 000 • 0.5 to 250 ("000" sets 0V stop)
(Hz) 0.1 (0.5 to 100Hz) 1 (100 to 250Hz)
Frequencies that exceed the maximum output frequency and the upper frequency
clamp will not be output.
(sec) 0.1 to 999
(sec) 0.1 (0.1 to 100sec) 1 (100 to 999sec)