Problem
No power to the backup loads
while grid is OFF (power outage)
Inverter without auto-transformer
(On-grid only) - The inverter does
not start production and Error 182
Auto-Transformer Temp. Too
High is displayed

Error Codes

The error messages include an error number and a description, and have the following format:
E r r o r
C o d e
( 3 x D 2 )
< L i n e
1 >
< L i n e
2 >
XXX: The error number. The error code numbers may differ depending on the inverter 
type (single phase or three phase) as described in the table below.
(#-X#): A code indicating the source of error and the error information sent to the 
monitoring server. This information is used by SolarEdge Support for advanced 
troubleshooting..
Line 1-2: Error description
WARNING!
All Warnings and Cautions in this manual should be adhered to while troubleshooting an error.
Tous les avertissements et précautions mentionnés dans ce manuel doivent être aussi appliqués
en cas de dépannage.
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0
Description or possible cause
The backed-up loads are not
backed up
The thermal sensor cables are not
connected.
X X X
Appendix A: Troubleshooting
Troubleshooting
Figure 9) to supply power to the loads
until the inverter problem is solved.
Then move to position 1.
Check that the inverter is
o
producing power
Check that there are no errors on
o
the inverter LCD
Check the circuit breakers on the
o
backed-up loads AC panel
Check that the AC breaker in the
o
StorEdge Connection Unit are in
the UP position (see Figure 9)
Check that the AC bypass switch
o
in the StorEdge Connection Unit is
set to position 1 (see Figure 9) .
Move the DIP switch SW2 in the
StorEdge Connection Unit to the
UP position (ON) (refer to DIP Switch
Setup according to System Application
on page 38).