Warning Reference Codes - SolarEdge 2.2KW User Manual

Solar inverter for water pump
Table of Contents

Advertisement

Warning Reference Codes

Warning code
A01
PV input voltage is too low.
A02
Weak sunlight
A03
Dry running
A04
Overload
A05
Over current
A06
EEPROM error
A07
IGBT over temperature warning
A08
Over temperature warning
A09
Over temperature
A10
Wrong parameter setting in the
motor.
A11
Water tank is full.
A12
Water tank is dry.
A13
Well is dry.
Warning type
16
Possible Cause
1. PV input voltage is too low.
2. Sunlight is too weak.
Sunlight is too weak
Water level in the well is low.
1. The motor is suddenly locked.
2. The pump head is too high.
3. Wrong current setting on the motor.
1. The motor is suddenly locked.
2. Wrong current setting on the motor.
There is something wrong with EEPROM circuit.
Over temperature on IGBT.
Over temperature warning
1. Environment temperature is beyond the upper
limit.
2. The
wire
of
environment
detection is not connected.
Wrong parameter setting in the motor.
Water tank is full.
No water or water in low level in the water tower.
No water or water in low level in the well.
temperature