Specifications

9 Specifications
Enclosure
Dimensions, W x H x D [mm (in)]
Weight
Protection
Mounting
Spring-action plastic mounting clips
Connections
Soft starter
Contacts
Networks
Settings
IP address
Device name
Network
Link speed
Full duplex
Auto crossover
9
9
Power
Consumption (steady state, maximum)
Reverse polarity protected
Galvanically isolated
Certification
RCM
CE
ODVA
Environmental
Operating temperature
Storage temperature
Humidity
Pollution degree
Vibration
24
EtherNet/IP Module
-10 to +60 °C (14–140 °F), above 40 °C (104 °F) with derating
Danfoss A/S © 05/2017 All rights reserved.
40 x 166 x 90 (1.6 x 6.5 x 3.5)
250 g (8.8 Oz)
6-way pin assembly
BootP, automatically assigned, configurable
10 Mbps, 100 Mbps (auto-detect)
35 mA at 24 V DC
EtherNet/IP conformance tested
-25 to +60 °C (-13 to +140 °F)
5–95% relative humidity
Pollution degree 3
IP20
2
Gold flash
RJ45
Configurable
IEC 60947-4-2
IEC 60947-4-2
IEC 60068-2-6
MG17Q102