Packet Structures

7.3.3.3 Status Codes for Acyclic Services

Status
Status name
code
0x00
Success
0x03
Invalid parameter value
0x05
Path destination unknown The mapped register does not exist.
0x08
Service not supported
0x09
Invalid attribute value
0x0E
Attribute not settable
0x14
Attribute not supported
0x16
Object does not exist
Table 7.14 Status Codes, Get/Set Attribute Single
MG17Q102
Installation Guide
Comments
This code is returned after successful execution of the service, that is
When the register mapped for service Get attribute single is successfully read.
When the register mapped for service Set attribute single is successfully set.
The requested service is not available for this Object class/instance.
This code only applies to the service Set attribute single. It is returned if the value is out of range
for the mapped register.
This code only applies to the service Set attribute single. It is returned if the mapped register is
read-only.
The attribute specified in the request is not supported.
The object specified does not exist in the device.
Danfoss A/S © 05/2017 All rights reserved.
7
7
21

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT Compact Starter MCD 201 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Vlt compact starter mcd 202Vlt compact starter mcd 500

Table of Contents