Workstations Installation
Ethernet port 2:
– Use connector X5 (IP: 10.8.2.209, Netmask: 255.255.255.0, Gateway:
10.8.2.240);
– This port must be used for firmware upgrades. (It is possible to use Port 1, but
a few extra commands are needed);
– This port can be used after Linux has booted. It will send out video data and
can receive a TCP connection on port 4172 (Max 1 connection globally for
RIB6).
Video:
– Connect to J3;
– Termination can be selected using “SW5”. The following combinations are
possible:
Trigger pulse:
– Connect to J2;
– Termination can be selected using “SW2”. The following combinations are
possible:
Bearing pulse:
– Connect to X9;
– Termination can be selected using “SW3”. The following combinations are
possible:
Heading pulse:
– Connect to X9;
– Termination can be selected using “SW4”. The following combinations are
possible:
16
NAVI-SAILOR 4000/4100 ECDIS (v. 2.00.009). Installation Guide
50 Ohm
1: ON 2: OFF 3: OFF 4: OFF;
75 Ohm
1: OFF 2: ON 3: OFF 4: OFF;
1,2 kOhm
1: OFF 2: OFF 3: ON 4: OFF.
50 Ohm
1: OFF 2: ON 3: OFF 4: OFF;
75 Ohm
1: OFF 2: OFF 3: ON 4: OFF;
1,2 kOhm
1: OFF 2: OFF 3: OFF 4: ON.
560 Ohm pull-up
1: ON 2: OFF 3: OFF 4: OFF;
1,2 kOhm
1: OFF 2: ON 3: OFF 4: OFF;
Composite mode
1: OFF 2: OFF 3: OFF 4: ON.
560 Ohm pull-up
1: ON 2: OFF 3: OFF 4: OFF;
1,2 kOhm
1: OFF 2: ON 3: OFF 4: OFF;
Composite mode
1: OFF 2: OFF 3: OFF 4: ON.