NS 4000 Hardware Components
Signal output DC OK floating:
– Output description: relay contact, Uout > 0.9 x Un: contact closed;
– Voltage:
– Current:
– Status display: “DC OK” LED green/Uout < 0.9 x Un: LED flashing.
Signal output POWER BOOST active:
– Output description: Iout < In: high signal;
– Voltage: + 24 V DC;
– Current:
– Status display: LED “BOOST”, yellow/Iout > In: LED on.
General Data:
– Insulation voltage input/output: 4 kV AC (type test)/2 kV AC (routine test);
– Insulation voltage input/PE: 3.5 kV AC (type test)/2 kV AC (routine test);
– Insulation voltage output/PE: 500 V DC (routine test);
– Mounting position: on horizontal NS 35 DIN rail according to EN 60715;
– Degree of protection: IP20;
– Protection class: , with PE connection;
– MTBF: > 500,000 h according to IEC 61709 (SN 29500);
– Housing version: steel sheet, zinc-plated;
– Weight: 1.7 kg;
– Dimensions (width x height x depth) state of delivery: 90 x 130 x 125 mm;
– Dimensions (width x height x depth) 90º tuned: 122 x 130 x 93 mm.
Ambient conditions:
– Ambient temperature (operation): -25 ... 70 ºC (> 60 ºC derating);
– Ambient temperature (storage/transport): -40 ... 85 ºC;
– Max. permissible relative humidity (operation): 95% (at 25 ºC,
no condensation).
138
NAVI-SAILOR 4000/4100 ECDIS (v. 2.00.009). Installation Guide
30 V AC/DC;
1 A;
1 A (short circuit resistant);