NS 4000 Hardware Components
Interfaces Description
Table 18. Input/Output channels
Quantity
Data format
Parity
Baud rate
Data transfer
delay
Ethernet
Dimensions
164
NAVI-SAILOR 4000/4100 ECDIS (v. 2.00.009). Installation Guide
Description
16 x RS 422 bi-directional
channels (default configuration)
IEC 61162 ed. 1/2 (NMEA 0183)
Any type of binary data
None
Even
Odd
1200
2400
4800
9600
19200
38400
57600
115200
30 to 255 msec
2 (two) LAN 10/100 Mbits/sec
adapters
Fig. 62. DCU6. Dimensional drawing
Notes
114 ports are RS 422 bi-directional channels.
15 and 16 ports are RS 422 bi-directional
channels by default and may be configured by
jumpers X16 and X17 accordingly as follows:
Output channels transmit RS 232 signal;
Input channels receive RS 422 signal
Limitations:
In case if all 16 RS ports will be loaded
by bi-directional data transferring with baud rate
between 1200 and 38400 then no more than
25 Transas Workstations could work with same
DCU;
Baud rate 57600 then no more than
15 Transas Workstations could work with same
DCU;
Baud rate 115200 then no more than
10 Transas Workstations could work with same
DCU
Adjusted by operator