Kipor Sinemaster IG3000 Operation Manuals page 23

Digital generator
Hide thumbs Also See for Sinemaster IG3000:
Table of Contents

Advertisement

■ Before connecting an appliance to the generator, check that it is in good order,
and that its electrical rating does not exceed that of the generator.
Then connect the power cord of the appliance, and start the engine.
■ When generator is started, both the red light and green light may go on
simultaneously. It is normal that red light is out after 4 seconds. If the red light stays
on, consult your dealer.
5.3 DC use
DC sockets output voltage of DC 15-30V at zero load. The DC socket can only be
used to charge automatic battery of 12V.
DC output varies as the SMART energy saving switch positions differs.
DC current:
SMART Energy- saving switch
Model
1. Connect the DC socket of generator to battery terminal with charging cable.
■ In order to prevent spark, please connect charging cable to generator first, then
to battery, and dismantle first from battery.
■ Disconnect the grounding line of battery first, before charging cable is connected
to battery. Connect the grounding line of battery after dismantle charging cable.
Short circuit or spark may be prevented if you carelessly make the battery terminal
contact with auto frame.
NOTE
NOTE
IG3000
WARNING
Off
5.0A
17
On
(No AC output)
About 2.8A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinemaster ig4000