2.3 SMART Energy-saving switch
ON:
Generator would be at idle state if electrical appliance is disconnected from engine;
Engine would return to normal speed once connected with appliance. This equipment
is to reduce oil consumption in running.
■ (SMART) energy saving switch cannot run effectively when greater instant
power is needed.
■ Shut down energy saving switch to reduce voltage variation when generator is
connected with high electrical load.
■ Close energy saving switch during DC operation.
OFF:
Indicates that smart energy saving switch is closed and engine is at high rotation
speed.
2.4 LCD parameters display
2.4.1 Single-voltage LCD-230V
LCD will display the following parameters in cycle
after powered on:
No.
1
Genset voltage
2
Genset current
3
Genset frequency
4
Battery voltage
5
Accumulated running time
■ LCD back light lights for 10 seconds then goes out automatically once pushed
button.
■ When the current displayed parameter is not "genset voltage", displayed
parameter will switch to "genset voltage" automatically after 30 seconds.
CAUTION
Parameters
CAUTION
6
Unit
Note
1 V
V
1 A
A
0.1 A
0.1 Hz
Hz
0.1 V
V
0.1 Hour
Hr