TouchWand Wanderfull Technical Manual page 20

Smart home hub
Hide thumbs Also See for Wanderfull:
Table of Contents

Advertisement

When clicking the Enable connection checkbox, the user is able to connect with the BitWise.
In the Listen on IP field, the user should enter the IP address. By entering 0.0.0.0 the user can
access connections from any IP address and 127.0.0.1 for local connections.
The controller creates a TCP server and listens to the clients on the port specified in the
settings (7443 as example entered in the Port field).
BitWise AV Controllers are designed for customizable control of sub-systems at home or any
other location. In case of BC2 controller or BC1 controller, the client is the bitwise controller
itself and the max clients number in settings of our controller can be set as 1 client. In case of
BC4 controller the max number of connections can be set by maximally permitted
simultaneous connections from user's mobile devices to the Wanderfull controller. The
number of connections should be entered in the Max Connections field.
The module or scriptDevice from BitWise is designed to enable Bitwise users to manage the
electrical circuits and scenarios defined in the Wanderful controller.
To set up the scriptDevice the user must configure controller's IP address, port and TCP
protocol. When the Wanderfull scriptDevice is installed on BC4 controller for example, the
user should also set the protocol to TCP GUI and set up SERIALPORT1 to GUI Two-Way (TCP).
Devices that perform functions of the script must have the following name format (two
fields): <ID>_<NAME>
- the device name can include only an ID number, without the name
- the ID number must be a real ID number corresponding to unit ID number in the Wanderfull
controller
- the unit ID and unit name must be separated by underscore character ("_")
- the name field can contain any asci characters (there is no validation on name field).
Scenario functions
- Persistent and user scenarios can be triggered only by an 'activation' function
- Dynamic scenarios can be only activated or deactivated. Dynamic scenario will not be
triggered by an 'activation' function.
Feedback
There are four kinds of feedback for each unit – value, text, state and name.
- value feedback: current value of the unit (in decimal percepts, in case of binary switch it will
be 0 or 255)
- text feedback: custom text label that is sent from the controller
- state feedback: 1 or 0 corresponding to unit current state
- name feedback: current name of the unit from the Wanderfull controller