HANDLING GUIDELINES

Adhere to the following handling guidelines for the evaluation
board:
Always treat the
ADGM1004
observe normal handling precautions, including working
only on static dissipative surfaces, wearing wrist straps, or
other electrostatic discharge (ESD) control devices.
Take care when connecting signals. Hold the
ADGM1004EBZ
from the edges to avoid any damage to the
device under test (DUT).
Avoid connecting live signal sources. Ensure that outputs
are switched off (preferably grounded) before connecting
as a static sensitive device and
EVAL-
Rev. 0 | Page 8 of 11
EVAL-ADGM1004EBZ User Guide
to the DUT. In addition, ensure all instrumentation shares
a common chassis ground.
Avoid running measurement instruments (for example,
digital multimeters (DMMs) in autorange modes). Some
instruments can generate large transient compliance
voltages when switching ranges.
Use the highest practical range (that is, lowest resolution)
setting for resistance measurements; this minimizes
compliance voltages.
Physically handle the
EVAL-ADGM1004EBZ
with care.