_____________________________________________________________________________________________________________
GMX500 Factory Default Data String:
Items in red relate to the GPS option unit.
NODE, DIR,SPEED, CDIR, CSPEED, PRESS, RH, TEMP, DEWPOINT, GPSLOCATION, TIME, VOLT, STATUS,
CHECK
┐Q,021,000.01,090,000.01,1015.3,041,+022.0,+008.5,+50.763004:-001.539898:+3.10,2015-06-
05T10:19:30.8,+05.1,0004,└ 36
Where
Q
021
000.01
090
000.01
1015.3
041
+022.0
+008.5
+50.763004
-001.539898
+3.10
2015-06-05
T10:19:30.8
+05.1
0004
36
NOTES:
<STX> is the Start of String character (ASCII value 2).
<ETX> is the End of String character (ASCII value 3).
Checksum, the 2 digit Hex Checksum sum figure is calculated from the Exclusive OR of the bytes between
(and not including) the STX and ETX characters.
MetSet Default Settings
REPORT : NODE DIR SPEED CDIR
STATUS CHECK
PROTOCOL : GILL
COMMS : RS232
BAUD : 19200
NODE : Q
__________________________________________________________________________________________________
MaxiMet
Doc. No. 1957-PS-021
STX
Node Letter
Wind Direction
Wind Speed
Corrected Direction
GPS Corrected Speed
Pressure
Relative Humidity
Temperature
Dewpoint
GPS Latitude
GPS Longitude
GPS Height location
Date
Time
Supply Voltage
Status
ETX
Checksum
CSPEED
PRESS RH TEMP DEWPOINT
SENSOR COMPASS : ON
COMPASSDECL : +000.0
SENSOR GPS : ON
UNITS GPS : MS
Page 47
GPSLOCATION
TIME VOLT
POWER : 0
TIME : 2015-06-05T11:04:54
AUTOTIME : ON
TZOFFSET : +00.00
Issue 3