Connector and Cable Assembly continued:-
1. Open the pack of connector parts supplied (Gill Part 1405-PK-069).
2. Arrange Backshell Parts.
3. Trim back the screened cable outer and screen sleeves 40mm.
4. Trim back the screen drain wires flush with the outer sleeve.
5. Strip back the connection wires by 5mm and tin solder.
6. Solder the contact pins to the wires (please note that the connector supplies the correct strain
relief for cables with an outside diameter of 6-12mm).
5mm
7. Put the parts on the cable in the order as shown below.
8. Whilst squeezing the red retainer in the direction of ARROWS A, pull in the direction of ARROW B.
A
Your connector should now resemble the connector in the picture below.
9. Insert each contact pin until you feel a slight click. If you have inserted the contact into the
incorrect hole it can be removed at this point by simply pulling it out. Please note there will be
some resistance.
Rear view of connector
__________________________________________________________________________________________________
MaxiMet
Doc. No. 1957-PS-021
Screen Twisted Pair Cable
40mm
Screen drain wires cut flush