_____________________________________________________________________________________________________________
GMX240 Factory Default Data String
Items in red relate to the GPS Option Unit.
NODE, DIR, SPEED, CDIR,
CHECK
┐Q,180,000.06,133,000.21,00000.000,000.000,+50.763060:-001.540268:+0001.60,2017-
11-02T15:07:27.6,+05.0,0004,└ 31
Where: ┐
Q
180
000.06
133
000.21
0000.000
000.000
+50.763060
Notes: <STX> is the Start of String character (ASCII value 2)
<ETX> is the End of String character (ASCII value 3)
Checksum, the 2 digit Hex Checksum sum figure is calculated from the Exclusive OR of the bytes
between (and not including) the STX and ETX characters
MetSet Default Settings
REPORT : NODE DIR SPEED CDIR
PROTOCOL : GILL
COMMS : RS232
BAUD : 19200
NODE : Q
OUTFREQ : 1HZ
MSGMODE : CONT
ASCTERM : CRLF
ECHO : ON
ALIGN : 0
SENSOR WIND : ON
UNITS WIND : MS
NODIR : 0.00
AVGSHORT : 60
AVGLONG : 10
__________________________________________________________________________________________________
MaxiMet
Doc. No. 1957-PS-021
CSPEED,
TOTAL PRECIP, PRECIP INTENSITY,
STX
Node Letter
Wind Direction
Wind Speed
Corrected Direction
GPS Corrected Speed
Precipitation Total
Precipitation Intensity
GPS Latitude
CSPEED
PRECIPT PRECIPI
SENSOR COMPASS : ON
COMPASSDECL : +000.0
SENSOR GPS : ON
UNITS GPS : MS
SENSOR TEMP : ON
UNITS TEMP : C
SENSOR PRECIP : ON
UNITS PRECIP : MM
GPSLOCATION,
-001.540268
+0001.60
2017-11-02
T15:07:27.6
+05.0
0004
31
GPSLOCATION
POWER : 0
TIME : 2017-11-02T15:07:27
AUTOTIME : ON
TZOFFSET : +00.00
PUPMSG STATUS : ON
PUPMSG REPORT : ON
PUPMSG UNITS : ON
MODBUS : RTU
MODADDR : 1
DATABITS : 8
STOPBITS : 1
PARITY : NONE
MODTERM : 10
MODICT : 1000
Page 42
TIME, VOLT, STATUS,
GPS Longitude
GPS Height location
Date
Time
Supply Voltage
Status
ETX
Checksum