A
_ _ _ COUNTER SETUP scrolls across the display, and SKIP appears. Press
skip to 8.3, or use the
B INPT (B input) or C INPT (C input), and then press
selected counter.
If you selected PRM CT or C INPT, continue to 8.2B now.
If you selected B INPT, skip to 8.2C now.
Note that the B INPT counter cannot be independently confi gured unless the count mode for
PRM CT is set to AB IND (see 8.2B). If you attempt to enter the B INPT counter setup when the
above condition has not been met, an error message will scroll across the display, and you will
not be allowed to continue.
B
_ _ _ COUNT MODE scrolls across the display, and the current count mode ap-
pears. Use the
will vary depending on which counter you are editing.) When you have made a
selection, press
If you are currently editing PRM CT, the menu options will be:
QUADX1, QUADX2, QUADX4, A+B, A–B, AB IND (AB independent) or
UP/DN (up/down).
If you are currently editing C INPT, the menu options will be:
COUNT, RSOFAB (reset to off set A, B mode) or RSOFST (reset to off set
and start A, B mode).
For more information on count modes, please see Section 6.
C
_ _ _ DECIMAL POINT POSITION scrolls across the display, and the current
decimal point position appears. Use the
0.1, 0.12, 0.123, 0.1234 or 0.12345, and then press
D
_ _ _ PULSES PER UNIT OF MEASUREMENT scrolls across the display, and the
current number of pulses appears. Adjust this value using the
tons, and then press
For example, if an encoder outputs 1,500 pulses/metre, set this value to 1500.
E
_ _ _ ENTER DISPLAY VALUE FOR X PULSES scrolls across, and the current
display value appears. ('X' is the number of pulses selected in 8.2D.) Adjust this
value using the
For example, if you selected 1,500 pulses in 8.2D, and 1,500 pulses = 1 metre, then enter 1
Copyright © 2016 Defi ne Instruments
and
buttons to select: PRM CT (primary counter),
and
buttons to select an option from the list. (Options
to accept and continue.
.
and
buttons, and then press
to enter setup for the
and
buttons to select NO DP,
to accept and continue.
.
PRO-CTR-MAN-16V03 (0128)
19
to
and
but-
Need help?
Do you have a question about the PRO-CTR200 and is the answer not in the manual?