SUN2000L-(2KTL-5KTL)
User Manual
Check Type
S2
S2
Step 3 Tap Start to start the check. After the check is complete, IPS State is displayed as Self-test
success.
----End
7.4.3.5 Starting or Shutting Down the SUN2000L
Procedure
Step 1 On the Operation console screen, choose Device maint > Inverter ON/OFF, and perform
operations as required.
Figure 7-30 Starting or shutting down the SUN2000L
Issue 02 (2017-12-12)
Description
The level 1
overfrequency
protection threshold
is 51.5 Hz and the
level 1
underfrequency
protection threshold
is 47.5 Hz.
The level 1
overfrequency
protection threshold
is 51.5 Hz and the
level 1
underfrequency
protection threshold
is 47.5 Hz.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 Operations on the Local FusionHome App
External Signal
Setting
Local Command
Setting
83