Overview Of Dc Power Supply - Cisco 4451 ISR Hardware Installation Manual

4000 series integrated services routers
Table of Contents

Advertisement

Remove and Replace Cisco 4000 Series ISRs Power Supplies

Overview of DC Power Supply

The DC power supply is only supported on Cisco 4451-X ISR, Cisco 4431 ISR, and Cisco 4351 ISR.
This section describes the installation procedure that is common for all Cisco 4400 and 4300 Series ISRs.
For the Cisco 4431 ISR, the input connector and plug must be UL recognized under UL 486 for field
wiring. The connection polarity is from left to right: negative (-), positive (+), and ground.
For the Cisco 4451-X ISR and Cisco 4351 ISR, the input connector and plug must be UL recognized
under UL 486 for field wiring. The connection polarity is from left to right: ground, negative (-), positive
(+).
The power supply has a handle that is used for insertion and extraction. The module must be supported
with one hand because of its length.
For Cisco 4431 ISR, the power supply DC input range is -48 to -60 VDC, and the maximum power is
350 W.
For Cisco 4451 ISR and Cisco 4351 ISR, the power supply DC input range is -48 to -60 VDC, and the
maximum power is 437 W.
Figure 6-31
1
3
Hardware Installation Guide for Cisco 4000 Series Integrated Services Routers
6-44
Install DC Input Power on Cisco 4431 ISR, page 6-46
DC Power Supply
1
3
2
4
Handle
DC power connector
Chapter 6
Install and Upgrade Internal Modules and FRUs
2
FAIL and OK LEDs
4
Ejector latch
OL-32185-02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4351 isr4331 isr4221 isr4431 isr4321 isr

Table of Contents