Connect WAN, LAN, and Voice Interfaces
Caution
To comply with the Telcordia GR-1089 NEBS standard for electromagnetic compatibility and safety,
connect Gigabit Ethernet ports using RJ-45 connectors for shielded twisted pair cable only to
intra-building or unexposed wiring or cable. The intra-building cable must be shielded and the shield
must be grounded at both ends. The intra-building port(s) of the equipment or subassembly must not be
metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are designed
for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue
4) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not
sufficient protection in order to connect these interfaces metallically to OSP wiring.
Never install telephone jacks in wet locations unless the jack is specifically designed for wet
Warning
locations. Statement 1036
Never touch uninsulated telephone wires or terminals unless the telephone line has been
Warning
disconnected at the network interface. Statement 1037
Class 1 laser product. Statement 1008
Warning
Hardware Installation Guide for Cisco 4000 Series Integrated Services Routers
3-28
Chapter 3
Install and Connect Cisco 4000 Series ISRs
OL-32185-02