Step 3 Select a camera to configure.
Step 4 Check Enable Defocus Detection.
Step 5 Optionally, check Save VCA Picture to save the captured defocus detection pictures.
Step 6 Drag the Sensitivity slider to set the detection sensitivity. Sensitivity range: [1-100]. The higher the
value, the more easily the defocus image will be detected.
Step 7 Set the arming schedule. Refer to Chapter 11.1 Configure Arming Schedule.
Step 8 Set the linkage actions. Refer to Chapter 11.2 Configure Alarm Linkage Actions.
Step 9 Click Apply.

12.12 PIR Alarm

Purpose
A PIR (Passive Infrared) alarm is triggered when an intruder moves within the detector vision field.
The heat energy dissipated by a person or any other warm blooded creature such as dogs, cats, etc.,
can be detected.
Step 1 Go to System > Event > Smart Event.
Step 2 Click PIR Alarm.
Network Video Recorder User Manual