Identification And Maintenance Functions (I&M) - ABB RETA-02 User Manual

Ethernet adapter module
Table of Contents

Advertisement

90
Positive Read response to Read request:
Negative response to PROFIdrive Read request:
01 01 B0 2F 08 05 81 01 01 44 01 00 14
Identification and maintenance functions (I&M)
The purpose of the I&M functions is to provide support for the
customer during commissioning, parametrization and repair of the
module. RETA-02 supports I&M functions 0 - 4, which can be
accessed with a qualified configuration tool (like DTM Tool) or
using the Record data object's read request.
Communication
Slot number
Subslot number
Index
01 01 B0 2F 08 05 01 01 01 42 01 05 64
Response
Slot number
Subslot number
Index
Data length
Response
Data length
Response reference (mirrored)
Response ID
DO-ID
PROFIdrive Parameter Channel
Response reference (mirrored)
Response ID
Axis (mirrored)
Number of parameters
PROFIdrive Parameter Channel
Number of parameters
Format (0x42 = Word)
Number of values
Parameter value
Format (44h = Error)
Number of values
PROFIdrive error code