Parameter data transfer examples

The following example shows how parameter data is transferred
using the acyclic parameter access mechanism's READ and
WRITE.
Note: Only the part of the acyclic frame is presented in the
examples. The padding zeroes are not presented.
Example 1: Reading a drive parameter
To determine the parameter number and subindex for drive
parameter reading, multiply the parameter number by one
hundred and then convert it to hexadecimal. The low byte is the
subindex (IND), and the high byte is the parameter index (PNU).
For example, drive parameter number 12.04 corresponds to 12.04
× 100 = 1204 = 0x04B4.
Write request (Read parameter value):
Slot number
Subslot number
01 01 B0 2F 0A 05 01 01 01 10 01 00 04 00 B4
Command
Index
Data length
Request reference
Request ID (0x01 = Request Parameter)
PROFIdrive Parameter Channel
DO-ID
Number of parameters
Attribute (0x10 = Value)
Number of elements
89
Parameter index
Subindex