1

1.8 Absolute Maximum Ratings

Table1.8.1 lists the absolute maximum ratings of M3A-HS60.
Symbol
VCC
5V System Power Supply Voltage
3VCC
3.3V System Power Supply Voltage
1.2VCC
1.25V System Power Supply Voltage
Topr
Operating Ambient Temperature
Tstr
Storage Ambient Temperature
Note: The ambient temperature refers to the air temperature in the closest place from the board.

1.9 Recommended Operating Conditions

Table1.9.1 lists the recommended operating conditions of the M3A-HS60.
Symbol
VCC
5V System Power Supply Voltage
3VCC
3.3V System Power Supply Voltage
1.2VCC
1.25V System Power Supply Voltage
Maximum Power Consumption in the Board
Topr
Operating Ambient Temperature
Rev.1.00 June 1,2005
REJ11J0002-0100Z
Table1.8.1 Absolute Maximum Ratings of M3A-HS60
Parameter
Table1.9.1 Recommended Operating Conditions of M3A-HS60
Parameter
Rated Value
-0.3V to 6.0V
Relative to VSS
-0.3V to 4.6V
Relative to VSS
-0.3V to 1.7V
Relative to VSS
-5°C to 55°C
No dewdrops allowed.
Use in corrosive gas environment prohibited.
-10°C to 60°C
No dewdrops allowed.
Use in corrosive gas environment prohibited.
Rated Value
4.75V to 5.25V
Relative to VSS
3.0V to 3.6V
Relative to VSS
(Normally supplied from regulator)
1.15V to 1.35V
Relative to VSS
(Normally supplied from regulator)
Within 1A
5°C to 50°C
No dewdrops allowed.
Use in corrosive gas environment prohibited.