In case of intervention by this safety device as a result of overheating, disconnect from the power supply and leave the motor
to cool until it reaches an acceptable temperature. Before re-using the pump, check to verify the reasons which caused the
motor to overheat.
Check to ensure that certified cables are used in accordance with current regulations, with three cross-sections (2 + earth) of
at least 0.75 mm², with a maximum length of 2 m for the cable. If the cable is longer, the cross-section must be increased in a
suitable manner pursuant to currently applicable regulations.

OPERATION

Never allow the pump to run dry (without water). This will cause damage to the shaft seal and internal plastic components.
STARTING THE PUMP
In a flooded suction type application (pump below water level or in-line with primary pump), the pump starts as soon as the
shut-off valves in the inlet are opened.
In non-flooded applications, the pump must be primed by adding water within the suction piping and pump cavity.
The pump starts working after switching on. The suction action time depends on the suction height and the length of the suc-
tion line.
If the pump does not work, check that all shut-off valves are open and that there are no leaks in the suction line where air can
enter the water line preventing activation.

TROUBLESHOOTING

PUMP WILL NOT PRIME
MOTOR DOES NOT OPERATE
LOW FLOW - HIGH FILTER PRESSURE
LOW FLOW - LOW FILTER PRESSURE
NOISY PUMP
HEATING OF MOTOR
Insufficient water in pump casing
Primary pump not providing water
Incoming valve closed
Air leak in suction line
Power is off
Circuit breaker has tripped
Pump is off by time controlled unit
Motor connection is incorrect
Impeller is blocked by debris
Filter is dirty
Restriction in return line
Inlet plumbing is blocked
Impeller is blocked by debris
Air leak in suction line
Motor rotation is incorrect
Air leak in suction line
Debris in plumbing lines or pump housing
Diameter of suction line is too small
Incorrect pump installation
Cavitation (restriction of water)
Insufficient ventilation of motor
Size of wiring is too small