Download Print this page
STA-RITE P6E6C-204L Owner's Manual

STA-RITE P6E6C-204L Owner's Manual

Series p6ra, p6ea, p6e and p6r
Hide thumbs Also See for P6E6C-204L:

Advertisement

This manual must be given to the owner/user of this pump
© 2014 Pentair Water Pool and Spa, Inc. All rights reserved.
1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000
Max-E-Pro™, Sta-Rite® are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United
States and/or other countries. Unless noted, names and brands of others that may be used in this document are not used to indicate an affiliation or
endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the
trademarks or registered trademarks of those parties or others.
5/16/14
MAX-E-PRO
CENTRIFUGAL PUMPS
WITH INTEGRAL TRAP
O W N E R ' S
INSTALLATION, OPERATION & PARTS
Series P6RA, P6EA, P6E and P6R
See Page 2 for Model Numbers
®
M
A N U A L
S691 (Rev. C)

Advertisement

loading

Summary of Contents for STA-RITE P6E6C-204L

  • Page 1 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000 Max-E-Pro™, Sta-Rite® are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/or other countries. Unless noted, names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc.
  • Page 2 PUMP WARNINGS AND SAFETY INSTRUCTIONS For Pool and Spa Pumps (Non SVRS Pumps) FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESULT IN SERIOUS BODILY INJURY OR DEATH. THIS PUMP SHOULD BE INSTALLED AND SERVICED ONLY BY A QUALIFIED POOL SERVICE PROFESSIONAL.
  • Page 3 PUMP (Non SVRS) WARNINGS AND SAFETY INSTRUCTIONS TO MINIMIZE THE RISK OF INJURY DUE TO SUCTION ENTRAPMENT HAZARD: • Pools and spas should utilize a minimum of two drains per pump. A properly installed and secured ANSI/ASME A112.19.8 approved anti-entrapment suction •...
  • Page 4: Table Of Contents

    MANUAL CAREFULLY! potential for personal injury. The Sta-Rite ‘P6RA’, ‘P6EA’, ‘P6R’ and ‘P6E’ Series Self-priming Centrifugal pumps: warns about hazards that will cause death, serious personal injury, or major property damage if •...
  • Page 5: Installation

    NOTICE: Port threads are: Internal - 2" NPT for direct NOTICE: These parameters apply to Sta-Rite connection to pipe. External - 3-1/4" Buttress. Fits Sta-Rite equipment only. For non-Sta-Rite equipment, consult U11-200P Union Collar for quick disconnect pipe connection.
  • Page 6 Fittings restrict flow; for best efficiency use fewest Fire and burn hazard. Modern motors run at possible fittings. high temperatures. To reduce the risk of fire, do not allow Avoid fittings which could cause an air trap. leaves, debris, or foreign matter to collect around the Pool fittings must conform to International Association of pump motor.
  • Page 7: Electrical

    Water Velocity Voltage/Phase Voltage at motor must be not more than 10% above or The maximum water velocity through any suction outlet below motor nameplate rated voltage or motor may must be 1.5 feet per second unless the outlet complies overheat, causing overload tripping and reduced with the latest ASME/SNSI Specification for Suction component life.
  • Page 8 1. Turn off power. BONDING 2. Remove the motor end cover. To Wire a Single Speed, Single Voltage Motor There are two terminals labeled L1 and L2. Attach the power GREEN leads to these terminals. Either wire may attach to either GROUND SCREW terminal.
  • Page 9 Ground (Green) Low Speed Volt Back of Lines Common motor with Power Supply for Optional Timer. Terminal Board High Speed Circuit Remote SPDT Protector Switch If using timer, Connect Timer Motor to Low Speed Only 4558 0304 Minimum switch and timer amp rating must equal Branch Fuse Rating given in "Recommended Fusing and Wiring Data"...
  • Page 10 TABLE II - RECOMMENDED FUSING AND WIRING DATA - P6EA MODELS Serv.to Motor-Dist.in Ft(M) TABLE III - RECOMMENDED FUSING AND WIRING DATA - P6RA MODELS Serv.to Motor-Dist.in Ft(M) Wire Size Note: Wire gage calculated to prevent the voltage drop from exceeding 3 percent of supply voltage for the P6R6 Single and 3 Phase models.
  • Page 11: Operation

    OPERA TION If pump is not in a flooded suction system, remove trap cover handle ring and trap cover; fill trap and pump with DO NOT run the pump dry. If the pump is run dry, water. the mechanical seal will be damaged and the pump will start Do not lubricate the trap cover O-Ring.
  • Page 12: Storage/Winterizing

    Pump should only be serviced by qualified personnel. Do not use a wrench, this may For best results, use only genuine Sta-Rite factory damage the trap cover handle ring which can cause property damage or personal injury.
  • Page 13 Pump Disassembly/Removing Old Seal Pump Reassembly/Installing New Seal 1. Ceramic seat must be clean and free of dirt, grease, Disconnect power to pump motor. dust, etc. Wet outer edge of rubber cup on ceramic Be sure gate valves on suction and return piping seat with small amount of liquid detergent;...
  • Page 14: Troubleshooting Guide

    TROUBLESHOOTING Electrical: GUIDE 9. Pump may be running too slowly; check voltage at Read and understand safety and operating motor terminals and at instructions in this manual before doing any work meter while pump is on pump! running. If low, see wiring instructions or consult Only qualified personnel should electrically test power company.
  • Page 15: Repair Parts List

    P6E, P6EA, P6RA MAX-E-PRO POOL PUMP 1/2 through 3 HP Models Box A REPAIR PARTS LIST Part Part For quick disconnect pipe Description Qty. connections, purchase separately: Pkg. 188 2" Slip 1/2 Union Kit or Motor See page 14/15 Pkg. 189 2" NPT 1/2 Union Kit. #10-32x1/2”...
  • Page 16 Key Nos. 1(Motor), 10(Impeller), and 11(Diffuser) are listed below. Motor No. Impeller Diffuser (Key No. 1) (Key No. 10) (Key No. 11) Model No. 1 PHASE 60 HZ PUMPS 115/230 V 1- Speed P6E6C-204L AE100CHL C105-238PX C1-271P1 P6E6D-205L AE100DHL C105-238P C1-271P1 P6R6D-205L 355021S...
  • Page 18 Notes...
  • Page 19 Notes...
  • Page 20 All Pentair trademarks and logos are owned by Pentair or one of its global affiliates. Pentair Aquatic Systems™, Max-E-Pro® and Sta-Rite® are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other countries.