ADA Floor Space Requirements for Wheel Chair Manoeuvring
The owner may request the activation device location; however, the press switch must be in view of the door and not directly on the
door or frame. Please refer to ANSI 117.1 Safety Code for further guidelines on switch requirements.
Position #1:
should be a minimum of Two feet (2') from the door latch.
Position #2:
should be a minimum of Five feet (5') from the door face.
NOTE: Activation switches shall have a minimum height of 36" and a maximum height of 48" from finished floors.
Position #1
Position #2
External and Internal Factors
Door Condition
Door must move easily open and close (latch) without excessive force; weather stripping and threshold must not interfere with
door movement.
Reveal
For out swing (push) doors, the reveal must be within the range of 0" to 14" and within 0" to 4" for in swing (pull) doors.
Consult factory for special reveals.
Wind
When installing on a door in a strong wind condition area, special adjustments should be made to the arm and doorstop position,
to increase the spring tension.
Power/Control Wires
Check that the electrical feed, all conduits, and electrical junction boxes (for push plates or other activation devices, if required)
are correctly located in accordance with final approved shop drawings and within the guidelines of the enforced local electrical
codes.
The 115±5VAC supply lines are connected to the black primary wires coming from the transformer and the ground wire is attached to
the opener header box.
The controller board settings have been pre-set prior to shipment. It will be necessary for the door opener to be functional while
adjustments and settings are made. A black push actuator is mounted on the upper left corner of the circuit board to ease in the
adjustment process. Power up the unit and push an activating device and check to make sure that the splined pinion drive rotates in
the correct direction. Keep all wires away from moving parts and sharp edges that may cut into the outer casing of the wires.
NOTE: THE GROUND WIRE FOR THE INCOMING 115±5VAC POWER AND THE SYSTEM GROUND WIRE CANNOT SHARE THE SAME
GROUNDING STUD. GROUND THE INCOMING 115±5VAC ACCORDINGLY.
NOTE: Installation of any extra wiring for controls or accessories into the header unit shall be secured away from any moving parts.
WARNING: If the motor is not plugged into the circuit board, there is no resistance against the spring when manually opening the
door. The door or arm will close very quickly if opened.

4.0 INSTALLATION CONSIDERATIONS