WebDoor CADET PRO Installation And Instruction Manual page 26

Non-handed low energy swing door opener
Table of Contents

Advertisement

CODE INDICATION
FUNCTION
SETTING
LED
LED
A
0
A
1
A
2
A
4
To obtain the number of opening cycles that the door has gone through press the set button while in the Function
A, Setting 4 mode. Example: Readout of 3 2 (pause) 7 0 = 3,270 door cycles
A
5
A5 –
Door Opening
LED OFF
Door Fully Open
(Overhead
Door Closing
Sensor)
Door Fully Closed
A5 –
Door Opening
LED ON
Door Fully Open
(Door
Door Closing
mounted
Door Fully Closed
Sensor)
Table 3: Run Status Specifications (continued on the following page)
Run Status Display Specification
ON/OFF LED = ON
Safety 2 OFF at back check.
ACT=N1 is connected to a push button
switch and always opens the door.
ACT=N2 is connected to the door and is
only active after ACT'N1 is pressed and
before the door closes and gets to the
Latch point.
Lockout ON – during closing Safety1 is
active if the door stops moving (from
hitting an obstruction for example). If
door is moving then Safety1 is NOT
active.
In process of reading out # of door
opening cycles
Safety1 sensor mounted on closing side
of door.
- Safety1 sensor has no effect
- Safety1 sensor ON = door will not close
- A2 setting ON. Door moving = Safety1 has no effect (door will open)
- A2 setting ON. Door stopped, Safety1 ON = door will not open
- A2 setting OFF. Safety1 ON = door will not open
- Safety1 sensor ON = door will not open
- Safety1 sensor has no effect
- Safety1 sensor ON = door will not close
- Safety1 sensor ON = door drives at HOLD speed
- Safety1 sensor has no effect
Page 25 of 31
WebDoor
info@webdoor.com
www.webdoor.com
Issued Date: 2017-03-28
ON/OFF LED = OFF
Safety2 always active
Activation input 1 (ACT=N1)
works as an instant activation.
Activation input 2 (ACT=N2)
works as a delayed activation
(delay time programmed
through Function 5)
Lockout OFF
Safety1 is always active
No readout
Safety1 sensor mounted
overhead.
DEFAULT
SETTING
LED OFF
LED OFF
ACT=N1 = instant
and
ACT=N2 = delayed
activation
LED ON
Lockout ON
LED OFF – no
readout
LED OFF – Safety1
mounted
overhead.