WebDoor CADET PRO Installation And Instruction Manual page 22

Non-handed low energy swing door opener
Table of Contents

Advertisement

HANDICAP AND LOW ENERGY AUTOMATIC WITH DIGITAL PROGRAMMING
Digital Control Board Specifications
INPUTS
AC VOLTAGE
Table 1: Line Voltage
ACTIVATION1
- First input to open the door. Instant Activation.
(ACT=N1)
- ON = Closed contact to ground/common.
- See Function "A", Setting "1" for description of alternate operation.
ACTIVATION2
- Second input to open the door. Delayed Activation.
(ACT=N2)
- ON = Closed contact to ground/common.
- See Function "A", Setting "1" for description of alternate operation.
SAFETY1
- For Safety1 ON door will not open if presently fully closed and door will not close if presently fully opened
- ON = Closed contact to ground/common.
SAFETY2
- For Safety2 ON and activation1 input ON door will drive at hold speed. If activation1 input goes off door
- ON = Closed contact to ground/common.
OUTPUTS
MOTOR
- 2 motor connectors to drive door in either clockwise or counter clockwise direction.
DATA - AND DATA +
- interface with presence sensor. (Replaces LO-21K lockout relay)
OTHER FEATURES
CLOSING SPEED
- Adjustable by potentiometer.
BACK CHECK and
- One (1) switch for each.
LATCHING
LOCKOUT
- Lockout of door while closing is selectable via Function A", Setting 2".
OVERLOAD
- Selectable Overload setting, adjustable by potentiometer.
ON/OFF/HOLD OPEN
- Terminal block position to accommodate a 3 way switch for On, Off and Hold Open positions.
LINE VOLTAGE
120VAC 60Hz
120VAC 60Hz
240VAC 50Hz
240VAC 50Hz
(i.e. overhead presence sensor).
closes. If Safety2 goes off door will open (i.e. Door mounted sensor on swing side).
WebDoor
info@webdoor.com
www.webdoor.com
Issued Date: 2017-03-28
Low Energy
Low Energy
Low Energy
Low Energy
Page 21 of 31
TRANSFORMER (Hammond)
#166N24 – 24VAC – 4AMP
#166M16 – 16VAC – 3AMP
#266N24 – 24VAC – 4AMP
#266M16 - 16VAC – 3AMP