READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY! FAILURE TO DO SO MAY RESULT IN
PERSONAL INJURY OR PROPERTY DAMAGE!
2.
Install only on a properly operating and balanced door. A door that is operating improperly could cause severe injury.
Have qualified service personnel make repairs to cables, spring assemblies, and other hardware before installing the
opener.
3.
Remove all pull ropes and remove, or make inoperative, all locks (unless mechanically and/or electrically interlocked
to the power unit) that are connected to the door before installing the opener.
4.
Install the door opener at least 8 feet or more above the floor if the opener has exposed moving parts.
5.
Do not connect the door opener to the source of power until instructed to do so. Connection of the high voltage supply
should be done by a qualified professional and within the guidelines of the enforced local electrical codes.
6.
Locate the control station: (a) within sight of the door, (b) at a minimum height of 5 feet so small children cannot reach
it, and (c) away from all moving parts of the door.
7.
Install the Entrapment Warning Placard next to the control station in a prominent location.
8.
For products having a manual release, instruct the end user on the operation of the manual release.
9.
Test all safety features before turning over the equipment to the customer.
CADET PRO (Non-Handed)
LOW ENERGY SWING DOOR OPENER
Installation and Instruction Manual
WebDoor
866-262-5661
info@webdoor.com
www.webdoor.com
Issued Date: 2017-03-28

Advertisement

Table of Contents
loading

Summary of Contents for WebDoor CADET PRO

  • Page 1 CADET PRO (Non-Handed) LOW ENERGY SWING DOOR OPENER Installation and Instruction Manual READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY! FAILURE TO DO SO MAY RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE! Install only on a properly operating and balanced door. A door that is operating improperly could cause severe injury.
  • Page 2: Table Of Contents

    18.1.1 Activating Devices ................................29 18.1.2 Electric strike ..................................29 18.2 Header Cover Installation ................................29 18.3 Safety Decals ....................................29 18.4 Sticker Placement Example ................................30 18.5 Release for Service ..................................30 Page 1 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 3 Pull Arm RH Bronze WD-W5-505B Pull Arm LH Bronze Pull Track (Short) WD-W5-515C Pull Track Clear WD-W5-515B Pull Track Bronze WD-W5-517 Pull Track Roller Pull Track (Long) WD-W5-551 Pull Track Asm. Long-Clear Page 2 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 4: General Information

    Activation Devices The CADET PRO Opener is compatible with all devices using a dry contact switch, usually hardwired or radio controlled. All activation signals should be wired to Activation 1 and Common. When a door is used in a vestibule the built-in sequence can be used to allow both doors to operate in sequence.
  • Page 5: Technical Specifications

    Additional Fasteners Depending on Surface Level Shims Tape Measure Hand Saw/Power Saw Wire Stripper 2.0 TECHNICAL SPECIFICATIONS Model CADET PRO (Non-Handed) Low Energy Swing Door Opener Dimensions 4.125” (W) x 5.125” (H) x L (variable) Weight Approx 45lbs Power supply 115±5VAC, 60Hz, 3A Consumption...
  • Page 6: Intended Use

    (motor), torque production (gearbox), and a control system to interlink the two. The CADET PRO Opener ensures all-around safety. It can be combined with the full range of safety units, such as presence and motion sensors. It is easy to install for both new construction and retrofit application and can be adapted to a wide range of overhead concealed or surface applied installations.
  • Page 7 The CADET PRO Opener can be used for pull side and push side installation, on the top door jamb and in header applications. It is designed to meet the standards described in Section 1. Page 6 of 31 WebDoor info@webdoor.com www.webdoor.com...
  • Page 8: Installation Considerations

    WARNING: If the motor is not plugged into the circuit board, there is no resistance against the spring when manually opening the door. The door or arm will close very quickly if opened. Page 7 of 31 WebDoor info@webdoor.com www.webdoor.com...
  • Page 9: Installation Procedure

    Use two (2) screws to fasten the back plate directly to the doors vertical jambs on the hinge side. NOTE: Please reference the installation dimension an inch and a half from the hinge side of the door. Page 8 of 31 WebDoor info@webdoor.com www.webdoor.com...
  • Page 10 Fasten the bolts to hold the motor/gear box and control board as shown in the diagram shown in step 7. The motor/gearbox needs to be installed so that the center of the spindle is 5” (12.70 mm) from the end plate. Page 9 of 31 WebDoor info@webdoor.com www.webdoor.com...
  • Page 11: Opener Layout And Handing

    Insert spline shaft on the opener (depended on push or pull application and spindle rotation) Left Hand Installation Right Hand Installation (Label is down facing the floor) (Label is up facing the ceiling) Page 10 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 12: Changing Left To Right Push/Pull By Turning Opener Upside Down

    Re-attach gear box to opposite side of mounting plate and rotate mounting plate. Note that the arrow is now pointing upward. This indicates the handling is left hand pull. Connect wire harness and switch wiring (see wiring). Fully tighten all bolts. Page 11 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 13: Control Box Installation

    (push) opener, the control box is left of the gearbox motor. There is no need to secure the board in place, due to the mounting bracket that it comes with. Page 12 of 31 WebDoor info@webdoor.com www.webdoor.com...
  • Page 14: Arm Assembly Installation

    There are two (2) configurations available (see Options 1 and 2 below). The first hole on the door shoe should be 14” away from the door frame, and 2-1/4” from the top, for standard swinging doors. Page 13 of 31 WebDoor info@webdoor.com www.webdoor.com...
  • Page 15 If needed, loosen set screws for minor adjustment of door position. Step 4 Set three-position switch to Automatic (-) and allow door to close under spring pressure. Test and adjust if necessary. Page 14 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 16: Pull Arm Installation

    Step 4 a. Fit slide track in line with 1 and 2 mark and fix to the door. Turn three-position switch to automatic (I). b. Test and adjust if necessary. Page 15 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 17: Opener Tuning (Latch & Back Check Adjustment)

    (LED 1/2 – 0~5 in 6 steps) WARNING: Proximity Switch MUST engage at open or close, otherwise door will not operate correctly and power fuse may be blown (overload). Page 16 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 18: How Doors Operate

    Power will remain ON and supplied to the unit, however all signals will be ignored. The door can be opened easily with minimum force. Page 17 of 31 WebDoor info@webdoor.com www.webdoor.com...
  • Page 19: Modifying Spring Tension

    Turn Overload pot fully counter-clockwise – followed by ¼ turn clockwise. Red Overload LED should not go ‘ON’ when opening. Test with obstruction – door will cut power after about 2 seconds and close by spring pressure. Page 18 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 20 OVERLOAD IS THE TORQUE ADJUSTMENT SETTING FOR THE AMOUNT OF PRESURE WITH WHICH THE DOOR PUSHES AGAINST AN OBSTRUCTION, BEFORE CUTTING OFF FOR SAFETY. Overload POT - Basic Setting Position for a Standard Door Page 19 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 21: Door Control With Digital Programming

    Note: A Switch or Jumper must be wired from the ON terminal to the OFF terminal for Programming to work. This is only needed if there is no switch on the board. Page 20 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 22 - Lockout of door while closing is selectable via Function A", Setting 2". OVERLOAD - Selectable Overload setting, adjustable by potentiometer. ON/OFF/HOLD OPEN - Terminal block position to accommodate a 3 way switch for On, Off and Hold Open positions. Page 21 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 23: Programming

    The push button switches are labelled PASS and SET. Pressing the PASS button, will select the next function. Pressing the SET button, will change the present function value (when the slide switch is in PROGRAM mode). DIGITAL CONTROL BOARD Page 22 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 24 Note: A Switch or Jumper must be wired from the ON terminal to the OFF terminal for Programming to work. This is only needed if there is no switch on the board. Page 23 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 25 STRIKE DELAY 1 = 0.25sec 5 = 2.00sec The time between Strike ON and door 2 = 0.50sec starting to open. HA board ONLY 3 = 1.00sec Table 2: Programming Specifications Page 24 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 26 - Safety1 sensor ON = door drives at HOLD speed mounted Door Fully Closed - Safety1 sensor has no effect Sensor) Table 3: Run Status Specifications (continued on the following page) Page 25 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 27 Repeat on the other side of the opening if the door has two-way operation. NOTE: if there is more than one push plate on each side of the door, each push button should be tested. Page 26 of 31 WebDoor info@webdoor.com www.webdoor.com...
  • Page 28: Troubleshooting

    Make sure the 3 position switch (I 0 II) is set to automatic mode (I) If the problem persists, contact your authorized WedDoor representative for service. Page 27 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 29: Ada Adjustments

    17.0 ADA ADJUSTMENTS Adjust the WebDoor Automatic opener to the ANSI A156.19 standard for low energy operated doors. Adjust the automatic opener to the ANSI A156.19 standard for low energy operated doors. The following specifications are based on neutral air pressure conditions.
  • Page 30: Installation Wrap Up

    Analog board – strike out +ground, jumper between strike in + 24DC Digital Board – N.O. + GND After all adjustments have been finished, the face cover must be installed to the back plate by snapping cover into position. Page 29 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 31: Sticker Placement Example

    Before leaving the job site, please ensure the following is complete: Make sure all bolts are tight. Remove any tools, trash/debris from the work area. Verify all safety decals are installed. Final cleaning of glass. ©Entrematic Group AB 2017 Page 30 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...
  • Page 32 Series Model: CADET PRO (Non-Handed) LOW ENERGY SWING DOOR OPENER ©Entrematic Group AB 2017 This page intentionally left blank. This page intentionally left blank. Page 31 of 31 WebDoor info@webdoor.com www.webdoor.com Issued Date: 2017-03-28...

Table of Contents