Basic Operation
When the door receives activation, the door opens and brakes before the fully open position and opens slowly to the full doorstop
position, following the programmed data.
Once pre-set open period is complete, the door will close at the pre-set closing speed, braking to low speed a little before the
fully closed position and closes slowly.
When an activation signal activates while the door is closing, the door will stop and reverse to open.
Operation Switch
The operation switch is located on the side cover.
With the door in the closed position. Check that the door is unlocked and the main power switch is on. (A main power isolator
switch should be positioned to the side of the header)
Check the status of the 3-position switch.
Automatic Mode
The switch should be set to the (I) automatic position for activation.
Activate the push button or Knowing Act device. The door opens to approximately the 80 degree position at full speed, and
then will slow for the final 10 degrees of opening until full open is complete. (There is no need for a learning cycle as the open
position is already pre-set during installation)
After the pre-set open time is complete, the door will begin to close at the set closing speed, until the final 10 degree of
closing, when the door will slow for the final 10 degree of closing until the full latch position.
Hold Open Mode
The switch should be set to the (II) Hold Open position in order to hold the door open automatically for an extended length of
time.
No Activation or Safety sensor signals will be active in this mode as the door is stationary in the open position. The door will
remain held open continually by a pulsed signal to the motor without overheating. To close the door, move the switch to
either automatic (I) or off position (0) and the door will close smoothly and gently to the full closed position.
Off Mode
The switch should be set to the (0) off position. No Activation signals or (Safety sensor signals if equipped) will be active in
this mode as the door is stationary in the closed position. Power will remain ON and supplied to the unit, however all signals
will be ignored. The door can be opened easily with minimum force.