CODE INDICATION
FUNCTION
SETTING
LED
LED
A
6
A
7
A
8
note1: When setting up Code A8 it is important to 1. Turn the overload all the way down (counter clock wise on
the potentiometer) and 2. To make sure that the Back Check speed is slow enough that it will not trigger the
overload while the door is fully open.
Table 4: Run Status Specifications (continued)
Reset To Default
Pressing both the SET and PASS buttons together, for 5 seconds, will reset the product to its original default settings.
Activation Devices - Push Plate / Button
Test the button by pressing it once. The door should swing smoothly to the open position and stop without impact. After a
time delay (normally 1s to 5s) the door should close smoothly.
Repeat on the other side of the opening if the door has two-way operation.
NOTE: if there is more than one push plate on each side of the door, each push button should be tested.
ON/OFF LED = ON
Safety1 sensor is a Normally Closed
input (N.C.)
Safety2 independent of Activation 1
Safety2 is ON = door holds
Safety2 is OFF = door opens
Fire door mode for California. Manually
pulling the door closed while it is fully
open will close the door ignoring all
activation triggers including Hold Open.
Turning to OFF resets this mode. See
note1
Page 26 of 31
WebDoor
info@webdoor.com
www.webdoor.com
Issued Date: 2017-03-28
ON/OFF LED = OFF
Safety1 sensor is a Normally
Open input (N.O.)
Safety2 works with Act'n1.
For Safety2 AND Act'n1 both
ON = door holds.
If Safety2 goes OFF = door
opens
If Act'n1 goes OFF = door
closes.
Door will not shut when
manually pulled closed.
DEFAULT
SETTING
LED OFF – Safety1
is Normally Open
LED OFF
Safety2 works with
Act'n1.
LED OFF