Condition
One invalid TEACH Point

3.7 Sync Master/Slave

Two Q4X sensors may be used together in a single sensing application. To eliminate crosstalk between the two sensors,
configure one sensor to be the master and one to be the slave. In this mode, the sensors alternate taking measurements
and the response speed doubles.
Important: The master sensor and the slave sensor must be programmed for the same Response Speed and Gain
and Sensitivity settings. The master sensor and slave sensor must share a common power source.
1. Configure the first sensor as the master; navigate:
2. Configure the second sensor as the slave; navigate:
3. Connect the gray (input) wires of the two sensors together.