TSM module
Label
Enablement
Led blink
External power
Input function
Loop monitoring
Door monitoring event
Monitoring time
Input Channel
Enablement
Channel Label
Assigned zone
(see: "Zone assignment)
Operating mode
Output channel
Enablement
Channel label
Trigger zone #1
(see: "Zone assignment)
Trigger zone #2
Trigger point #1
Trigger point #2
Trigger point #3
Silenceable
Trigger on event
Delay from alarm
Zones
Label
Enablement
Walk test
Detector warning
Delay to alarm
Drift compensation
Double knock
Smoke verification
Delay to alarm duration
On board programmable outputs default values
Enablement
Channel label
Trigger zone #1
Trigger zone #2
Trigger zone #3
Trigger zone #4
Trigger point #1
Trigger point #2
Trigger point #3
Silenceable
Active on disablement (where applicable)
Trigger on event
Delay from alarm
default values
See note (**)
Enabled
On
On
Door monitoring
Off
Fault
30s
Enabled
See note (**)
Address related
Style C, NO
Yes
See note (**)
Address related
None
None
None
None
Yes
Zone Alarm
Off
default values
Zone AAA(*)
Enabled
Off
Off
Off
Off
Off
Off
0s
Yes
tttt y(****)
none
None
None
None
None
None
None
Yes
Off
none
Off
QUICK START-UP PROCEDURE
General options
Investigation delay
Main fault delay
Delay to alarm
Silence duration
Reset
Loop 1 wires
Loop 2 wires
Loop 3 wires
Day/Night mode
SC1 disablement
PSTN communicator enablement
IP communicator enablement
NETWORK enablement
Delay from alarm #1
Delay from alarm #2
Delay from alarm #3
Delay from alarm #4
Delay from alarm #5
PSTN communicator
Tone check
Start playing after
Call attempts
Iteration
Call all telemonitoring numbers
Call all voice message numbers
Telephone number label
All Telephone numbers behavior
Trigger events
Message #1 to #7
Notes:
(**) Automatically assigned Module label.
The label is composed by a brief description of the devi-
ce followed by its address.
Automatically assigned Module channel label
The label is composed by a first part containing the mo-
dule acronym and address followed by the brief de-
scription of the channel using the acronym printed on
the module PCB.
xxx = module acronim
yyy= module address
For example "DDM098: Ingresso A" is the default label for
the input #1 of the FC410DDM module at address 98.
(****) tttt represent the on board output type (4 chars),
SC outpts -> tttt="SC "
Programmabel outputs -> tttt="OC "
y = output number
(*****) xx represent the telephone number ID (2 digits),
default values
300s
1m
60s
60s
2s
4 wires
4 wires
4 wires
Day mode
Enabled
Not operative
Not present
Disabled
0s
0s
0s
0s
0s
default values
On
Selection
3
3
No
No
TEL. NUMBER xx(*****)
None
Panel alarm, Panel Fault
Pre recorded
77