Fans - Carrier 30RBM 160 Installation, Operation And Maintenance Instructions

Air-cooled liquid chillers
Table of Contents

Advertisement

11.4 - Fans

Each fan motor assembly is equipped with a high-performance impeller made from recyclable composite material.
The motors are three-phase, with lifetime lubricated bearings and class F insulation (IP55 level).
According to regulation No. 327/2011 implementing directive 2009/125/EC with regard to eco-design requirements for fans
driven by motors with an electric input power between 125 W and 500 kW.
Product
Option
Overall efficiency
Measurement category
Efficiency category
Target efficiency level ERP2015
Efficiency level at optimum efficiency
point
Variable speed drive
Year of manufacture
Fan manufacturer
Motor manufacturer
Fan PN
Motor PN
Nominal power of the motor
Flow rate
Pressure at optimum energy
efficiency
Nominal Speed
Specific ratio
Relevant information to facilitate the
disassembly, recycling or removal of
the product at the end of life
Relevant information to minimise the
impact on the environment
*
Only for two-speed fans [1 per circuit/the others are Standard]
**
Only for two-speed fans [1 per circuit/the others are Option 15LS]
According to regulation No. 640/2009 and amendment 4/2014 implementing directive 2005/32/EC with regard to ecodesign
requirements for electric motors.
Product
Option
Motor type
Number of poles
Nominal input frequency
Nominal voltage
Number of phases
Motor included in the application
domain of the regulation 640/2009
and amendment 4/2014
Rationale for exemption
Ambient air temperature for which
the motor is specifically designed
*
Only for two-speed fans [1 per circuit/the others are Standard]
**
Only for two-speed fans [1 per circuit/the others are Option 15LS]
42
30RBM/30RBP
Standard or option 28 Option 12
%
39,3
40,9
A
A
static
static
N(2015) 40
N(2015) 40
43,9
44,2
NO
YES upstream of the
motor
See label on the unit
See label on the unit See label on the unit See label on the unit See label on the unit See label on the unit
Simonin
Simonin
Leroy Somer
Leroy Somer
00PSG000000100A
00PSG000000100A 00PSG000000100A 00PSG000000100A 00PSG000000100A 00PSG000000100A
00PPG000478400A
00PPG000480800A 00PPG000478500A 00PPG000464600A 00PPG000464500
kW
1,85
2,97
m
/s
4,28
5,31
3
Pa
170
216
rpm
954
1127
1,002
1,002
See the Maintenance
See the
manual
Maintenance
manual
See the Maintenance
See the
manual
Maintenance
manual
30RBM/30RBP
Standard or option 28 Option 12
Asynchronous
Asynchronous
6
6
Hz
50
60
V
400
400
3
3
NO
NO
Article 1.2.c).(ii)
Article 1.2.c).(ii)
°C
70
70
Option 15LS
Option 28B*
35,9
38
A
A
static
static
N(2015) 40
N(2015) 40
42,4
42,3
NO
NO
Simonin
Simonin
Leroy Somer
AOS/ Regal Beloit
0,83
2,09
3,12
4,07
95
195
712
966
1,002
1,002
See the
See the
Maintenance
Maintenance
manual
manual
See the
See the
Maintenance
Maintenance
manual
manual
Option 15LS
Option 28B*
Asynchronous
Dual-speed
asynchronous
8
6
50
50
400
400
3
3
NO
NO
Article 2.1
Article 2.1
70
68,5
Option 28C**
30RBP (VFD duty)
36,6
41
A
A
static
static
N(2015) 40
N(2015) 40
43,3
45,7
NO
YES upstream of the
motor
Simonin
Simonin
AOS/ Regal Beloit
Leroy Somer
00PPG000494700A
0,88
1,84
3,59
4,15
90
170
710
950
1,002
1,002
See the
See the Maintenance
Maintenance
manual
manual
See the
See the Maintenance
Maintenance
manual
manual
Option 28C**
30RBP (VFD duty)
Dual-speed
Asynchronous
asynchronous
8
6
50
50
400
400
3
3
NO
NO
Article 2.1
Article 1.2.c).(ii)
68,5
70

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents