For Devices With 3.5 Mm, Sma, Or 2.92 Mm Connectors - Keysight Technologies N5249A Configuration Manual

Pna-x series pna series pna-l series n522x/3x/4xa microwave network analyzers
Hide thumbs Also See for N5249A:
Table of Contents

Advertisement

For devices with K connectors (2.92 mm),
Mechanical calibration kits, continued
Electronic calibration kits
N4692A Microwave ECal: 10 MHz to 40 GHz, 2-ports.
Includes:
– Option M0F module with: N4692-60001 2.92 mm (f) to
2.92 mm (m) ECal module
– Option 00M module with: N4692-60002 2.92 mm (m) to
2.92 mm (m) ECal module
– Option 00F module with: N4692-60003 2.92 mm (f) to
2.92 mm (f) ECal module
– Option 00A adds:
– N4692-60021 2.92 mm (m) to 2.92 mm (m) adapter
– N4692-60022 2.92 mm (f) to 2.92 mm (f) adapter
Cables
Note: Keysight offers the following 2.4 mm test port cables. Adapters will be
necessary when using these cables for 2.92 mm measurements.
– 85133C
single, semi-rigid: 2.4 mm (f) to PSC-2.4 mm (f),
1
81 cm, 32 inches
– 85133D
set, semi-rigid:
1
– One 2.4 mm (f) to 2.4 mm (m), 53 cm, 21 inches,
p/n 85133-60001
– One 2.4 mm (f) to 2.4 mm (f), 53 cm, 21 inches,
p/n 85133-60002
– 85133E
single, flexible: 2.4 mm (f) to PSC-2.4 mm (f), 97 cm,
1
38 inches
– 85133F
set, flexible:
1
– One 2.4 mm (f) to 2.4 mm (f), 63 cm, 25 inches,
p/n 85133-60016
– One 2.4 mm (f) to 2.4 mm (m), 63 cm, 25 inches,
p/n 85133-60017
– 85133H
Single, flexible: 2.4 mm (f) to 2.4 mm (m),
1
63 cm, 25 inches
– N4421AK20 Single, flexible: 2.4 mm (f) to 2.4 mm (m),
91.4 cm, 36 inches
Adapters
– 11904A 2.4 mm (m) to 2.92 mm (m)
– 11904B 2.4 mm (f) to 2.92 mm (f)
– 11904C 2.4 mm (m) to 2.92 mm (f)
– 11904D 2.4 mm (f) to 2.92 mm (m)
– 11904S 2 4 mm to 2 92 mm
– Adapter set, contains 4 matched adapters
1
Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard male
connector.
Find us at www.keysight.com
For devices with 3.5 mm, SMA, or
continued
2.92 mm connectors
CalPod calibration refresh modules
CalPod calibration refresh modules allow in-situ calibration
refreshes to be performed at the push of a button without remov-
ing the DUT or connecting calibration standards. They're useful
for removing environmental effects such as cable movement,
thermal effects of cables, connectors, and adapters, as well as
connector and switch matrix repeatability errors, or whenever it
is desirable to ensure a current and valid calibration is present.
The modules are especially useful in thermal or thermal-vacuum
chamber testing.
– 85530B 20 GHz Ambient temperature CalPod calibration
refresh module
– 85531B 20 GHz Temperature-compensated CalPod
calibration refresh module
– 85532B 20 GHz Thermal-vacuum compatible CalPod
calibration refresh module
– 85540A 40 GHz Ambient temperature CalPod calibration
refresh module
– 85541A 40 GHz Temperature-compensated CalPod
calibration refresh module
– 85542A 40 GHz Thermal-vacuum compatible CalPod
calibration refresh module
– 85523B CalPod controller; Provides control for up to four
CalPods
– 85556A CalPod drive cable splitter; Allows control for up to
12 CalPods
– 85554A CalPod drive cable extension; 10 meter extension
cable; cascadable.
Page 30